Procedures: Regulatory Treatment and Certification<br />
Inspection of Grader Stations<br />
Dosage Temperature Reading<br />
240 g/m 3 (15 lb./1000 ft. 3 ) 24 hours @ 15.5° C<br />
(60° F) or above<br />
180 g oz. minimum concentration<br />
reading at 1/2 hour<br />
120 g oz. minimum concentration<br />
reading at 24 hours<br />
128 g/m 3 (8 lb./1000 ft. 3 ) 48 hours @ 15.5° C<br />
(60° F) or above<br />
100 g oz. minimum concentration<br />
reading @ 1/2 hour<br />
75 g oz. minimum concentration<br />
reading @ 24 hours<br />
50 g oz. minimum concentration<br />
reading @ 48 hours<br />
FIGURE 3-1-4 Dosage, Temperature, and Reading for Methyl Bromide Fumigation at<br />
Normal Atmospheric Pressure (NAP), Chamber or Tarpaulin<br />
Certification<br />
Period<br />
Movement from<br />
Infested or<br />
Exposed<br />
Portions of<br />
Regulated Area<br />
Once fumigated, the certification period lasts as long the treated area<br />
is protected from recontamination.<br />
When the equipment and articles are cleaned to the satisfaction of a<br />
PPQ Officer and the required PPQ Form 530, Certificate of Federal/<br />
State Domestic Quarantines, is attached to the equipment and articles,<br />
then movement of the equipment from infested or exposed fields to<br />
nonexposed portions of the regulated area is permitted.<br />
Inspection of Grader Stations<br />
All grader stations under compliance agreement will be inspected to<br />
insure that stipulations of the compliance agreement are being<br />
followed on a schedule determined by the appropriate<br />
officer-in-charge. See PPQ Form 519, Compliance Agreement on<br />
page A-1-30.<br />