3.15.3 General Flux Leakage Applications<br />

The main advantage of the flux leakage method over the eddy current method<br />

of flaw detection is that the flux leakage method has a much higher signalonoise<br />

ratio for even small flaws on rough surfaces.This greater inherent<br />

signalto- noise ratio is due to the nature of signal generation that occurs when<br />

the flux sensors cut the magnetic lines of leakage flux. Signals from inner and<br />

outer surfaces differ in both phase and amplitude. Continuous spectrum<br />

analyzers can be used to separate signals and direct them to different<br />

channels where they are filtered and detected with threshold discriminators.<br />