The appropriate depth of measurement with the Stresscan unit is 0.008 in.<br />

(0.2mm), 0.003 in. (0.07mm), and 0.0008 in. (0.02mm), which corresponds to<br />

a BN frequency range of about 500 Hz to 10kHz. Response time to full<br />

reading is about one second at a depth of 0.2mm. A built-in alphanumeric<br />

display indicates stress in English (ksi) or metric (N/mm 2 ) units. Red and<br />

green LED display columns provide rapid visual indications of proportional<br />

stress values. RS 232 series digital communications port and 0 to 4 V analog<br />

recorder outputs are also provided.<br />