Position<br />

Contains various settings for formatting the field on the screen.<br />

X<br />

Y<br />

Right Bar extends<br />

from left to<br />

right<br />

Upward Bar extends<br />

from down<br />

to up<br />

Links Bar extends<br />

from right to<br />

left<br />

Downward Bar extends<br />

from up to<br />

down<br />

Specifies the position of the upper left corner along the X axis (interval from the left display margin). Values<br />

for these parameters begin with 0 on the left margin and increase to the width of the display minus one pixel<br />

(on the right margin).<br />

Possible Settings for Full<br />

Graphic Displays<br />

Possible Settings for<br />

Semi−graphic Displays<br />

This field can be placed freely on the screen. Therefore, X can be set from<br />

0 to the width of the display minus the width of the field in pixels.<br />

On semi−graphic displays, such as those which can be connected to the<br />

C130 CAN Controller, fields can only be placed evenly on every sixth<br />

X−coordinate (X = 0, 6, 12, 18, etc.). On pure text displays the display of<br />

bar graphics is not possible.<br />

Specifies the position of the upper left corner along the Y axis (interval from the upper display margin).<br />

Values for these parameters begin with 0 on the upper margin and increase to the height of the display minus<br />

one pixel (on the lower margin).<br />

Possible Settings for<br />

Full Graphic Displays<br />

Possible Settings for<br />

Semi−graphic Displays<br />

The field can be placed freely in the display. Therefore, Y can be set from 0 to the<br />

height of the display minus the height of the field in pixels.<br />

On semi−graphic displays, such as those which can be connected to the CAN<br />

Controller C130, fields can only be placed evenly on every eighth Y−coordinate (Y<br />

= 0, 8, 16, 24, etc.). On pure text displays the display of bar graphics is not<br />

possible.<br />

Data Point<br />

Allows the connection of the variable which should be displayed with this output field.<br />

Source<br />

Assign...<br />

Used to input or display the connected variable.<br />

Possible Settings Name of a process variable of data type USINT or UINT.<br />

The Assign... button opens a dialog box to select a variable for the Source field. By<br />

default, only variables of suitable types are displayed.<br />

Status<br />

Contains various settings for formatting the field on the screen.<br />

Source Used to input or display the connected variable.<br />

Possible Settings Name of a UINT process variable<br />

Possible Values Bit 0 If 1, the output field is invisible.<br />