12.07.2015 Views

Compact body All-rounder

Compact body All-rounder

Compact body All-rounder

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Name (type)Specifications, Structure, etc.• Substantially suppresses power harmonics to realize theequivalent capacity conversion coefficient K5=0 in the "Harmonicsuppression guideline for consumers who receive high voltage orspecial high voltage".• Has the power regeneration function as standard.• Connects multiple inverters to enable common converter systemoperation.FeaturesHigh power factorconverterFR-HC- (H)K(FR-HCB)(FR-HCL01) (FR-HCL02)Provided appliancesFR-HC• SpecificationsType FR-HCApplicable invertercapacity (*1)Rated input voltage/frequency200V 400V ∗1 The applicable capacity to the high power7.5K 15K 30K 55K H7.5K H15K H30K H55K factor converter is the total capacity of the3.7K to 7.5K to 15K to 30K to 3.7K to 7.5K to 15 to 30K to inverters.7.5K 15K 30K 55K 7.5K 15K 30K 55K ∗2 The output voltage varies with the input voltageThree-phase 200V to 220V 50Hz Three-phase 380V to 460V 50/value.200V to 230V 60Hz60Hz∗3 Reactor 1 FR-HCL01, Reactor 2 FR-HCL02and Outside box FR-HCB are supplied with aorder of the high power factor converter (FR-HC)Rated input current (A) 33 61 115 215 17 31 57 110Rated output voltage (V) (*2) 293V to 335VDC 558V to 670VDC• Outline dimension(Unit: mm)High Power Factor ConverterReactor 1Reactor 2Outside BoxVoltage CapacityFR-HCFR-HCL01FR-HCL02FR-HCBW H D W H D W H D W H D7.5K 220 300 190 160 155 100 240 230 16015K 250 400 190 190 205 130 260 270 170190 320 16530K 340 550 195 220 230 170 340 320 18055K 480 700 250 210 260 225 430 470 360270 450 203H7.5K 220 300 190 160 150 100 240 220 160H15K 250 400 190 190 195 130 260 260 170 190 320 165H30K 340 550 195 220 215 140 340 310 180H55K 480 700 250 280 255 190 400 380 285 270 450 203200V400VHigh power factor converterHOutside boxHReactor 1, Reactor 2HPeripheralDevicesStandardSpecificationsOutlineDimensionDrawingsTerminal ConnectionDiagramTerminal SpecificationExplanationOperation panelParameter unitFR ConfiguratorWD• Attachment to enable insataltion of FR-E700 series on DIN rail.Selection tableModelFR-E720WInverter Capacity (kW)FR-UDA01 FR-UDA02 FR-UDA030.1K, 0.2K,0.4K, 0.75KD1.5K, 2.2K 3.7KWD* Install the reactor (FR-HCL01, 02) on horizontalplane.OptionsInstructionsInquiryWarrantyCompatibilityMotorParameterListExplanationsofParametersDIN rail mountingattachmentsFR-UDA• Approximate dimension 68671086715 15101706714.4ProtectiveFunctionsHook1288.73-M4 0.7 screwHook1288.74-M4 0.7 screwHook4-M4 0.7 screw8.7 128(Unit: mm)56

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!