Pr. 14V/F pattern matching applicationsV/FPr. 14 Load pattern selectionYou can select the optimum output characteristic (V/Fcharacteristic) for the application and load characteristics.This function is valid for V/F control only.For constant torque load(initial value)Pr. 14 = 0100%Output voltagePr. 3 Base frequencyOutput frequency (Hz)For constant torque elevatorloadFor vertical lift loadsAt forward rotation boost...Pr. 0 (Pr. 46)settingAt reverse rotation boost...0%Output voltage100%Pr. 0Pr. 46Pr. 14 = 2ForwardrotationReverserotationBase frequencyOutput frequency (Hz)For variable torque loadPr. 14 = 1100%Output voltagePr. 3 Base frequencyOutput frequency (Hz)For constant torque elevatorloadFor vertical lift loadsAt forward rotation boost...0%At reverse rotation boost...Pr. 0 (Pr. 46)setting100%Output voltagePr. 0Pr. 46Pr. 14 = 3ReverserotationForwardrotationBase frequencyOutput frequency (Hz)Pr. 17Logic selection of output stop signal (MRS)Pr. 17 MRS input selectionThe inverter output can be shut off by the MRS signal. Also, logicfor the MRS signal can be selected.When Pr. 17 is set to "4", the MRS signal from external terminal(output stop) can be changed to the normally closed (NC contact)input, and the MRS signal from communication can be changed tothe normally open (NO contact) input.MRS SignalSTF (STR)signalPr.Pr.Pr.The motor coasts to stopONONTimeSetting value "0" (initial value) Setting value "2"InverterOutput stopMRSSDOutput stop18 Refer to the section about Pr. 1.19 Refer to the section about Pr. 3.20, 21 Refer to the section about Pr. 7.InverterMRSSDFeaturesPeripheralDevicesStandardSpecificationsOutlineDimensionDrawingsOptionsInstructionsMotorInquiryWarrantyCompatibilityTerminal ConnectionDiagramTerminal SpecificationExplanationOperation panelParameter unitFR ConfiguratorParameterListPr. 15, 16Jog operationPr. 15 Jog frequencyPr. 16 Jog acceleration/deceleration timeYou can set the frequency and acceleration/deceleration time forjog operation. Jog operation can be performed from either of theexternal or the PU operation mode.Can be used for conveyor positioning, test operation, etc.ExplanationsofParametersProtectiveFunctionsOutput frequency (Hz)Pr. 20Pr. 15 JOG frequencysetting rangeJOG signalForwardrotationPr. 16ONReverserotationTimeForward rotation STFONReverse rotation STRONWhen setting parameters, refer to the instruction manual (applied) and understand instructions.28

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!