12.07.2015 Views

Compact body All-rounder

Compact body All-rounder

Compact body All-rounder

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LineupConnection with Peripheral DevicesFeaturesSymbol124Inverter Type-0.1K-Three-phase 200VFR-E720-Three-phase 400VFR-E740-Voltage100V class200V class400V classInverter CapacityEnclosed-typestructure (IP20)Totally enclosedstructure (IP40)Enclosed-typestructure (IP20)Totally enclosedstructure (IP40)FR-E720SymbolNoneSWNumber of Power PhasesThree-phase inputSingle-phase inputSingle-phase input(double voltage output)R/L1 S/L2 T/L3P/+ N/- U V WEarth(Ground)0.1K 0.2K 0.4K 0.75K 1.5K 2.2K 3.7K 5.5K 7.5K 11K 15KSingle-phase 200V Enclosed-typeFR-E720S- * structure (IP20)Single-phase 100V Enclosed-typeFR-E710W- * structure (IP20)*:Output of the single-phase 200V and single-phase 100V input specifications is three-phase 200V. :Available models :Models to be released :Not availableSymbol0.1K to 15KInverter CapacityRepresents theinverter capacity"kW".SymbolNoneCProtective StructureEnclosed-type structure IP20Totally enclosed structure IP40AC reactor (FR-HAL)Three-phase AC power supplyUse within the permissible power supplyspecifications of the inverter.Moulded case circuit breaker(MCCB) or earth leakage currentbreaker (ELB), fuseThe breaker must be selected carefullysince an in-rush current flows in theinverter at power on.Magnetic contactor (MC)Install the magnetic contactor to ensuresafety. Do not use this magneticcontactor to start and stop the inverter.Doing so will cause the inverter life to beshorten.Reactor (FR-HAL, FR-HEL option)Reactors (option) must be used whenpower harmonics measures are taken,the power factor is to be improved or theinverter is installed near a large powersupply system (500kVA or more). Theinverter may be damaged if you do notuse reactors. Select the reactoraccording to the model. Remove thejumpers across terminals P/+ - P1 toconnect the DC reactor.DC reactor (FR-HEL)P/+ P1Parameter unit (FR-PU07)By connecting the connection cable (FR-CB2) to the PU connector, operation can beperformed from FR-PU07.USB connectorA personal computer and an invertercan be connected with aUSB (Ver1.1) cable.P/+PRBrake resistor(FR-ABR, MRS, MYS)Braking capability can be improved.(0.4K or more)PeripheralDevicesStandardSpecificationsOutlineDimensionDrawingsTerminal ConnectionDiagramTerminal SpecificationExplanationOperation panelParameter unitFR ConfiguratorParameterListExplanationsofParametersProtectiveFunctionsComplies with UL, cUL, EN (LVD) standardsNoise filter(FR-BSF01, FR-BLF)Install a noise filter toreduce the electromagneticnoise generated from theinverter. Effective in therange from about 1MHz to10MHz. When more wiresare passed through, a moreeffective result can beobtained. A wire should bewound four turns or more.Radionoise filter(FR-BIF)Reducesthe radionoise.Noise filter(FR-BSF01, FR-BLF)Install a noise filter to reduce theelectromagnetic noisegenerated from the inverter.Effective in the range from about1MHz to 10MHz. A wire should bewound four turns at a maximum.MotorOptionsInstructionsMotorHigh power factorconverter (FR-HC)Power supply harmonicscan be greatly suppressed.Install this as required.Power regenerationcommon converter (FR-CV)Great braking capability is obtained.Install this as required.Brake unit(FR-BU2)P/+ PRP/+PRRegister unit (FR-BR)Discharging registor (GZG, GRZG)The regenerative braking capabilityof the inverter can be exhibited fully.Install this as required.Earth(Ground)Devices connected to the outputDo not install a power factor correction capacitor,surge suppressor or radio noise filter on the outputside of the inverter. When installing a moulded casecircuit breaker on the output side of the inverter,contact each manufacturer for selection of themoulded case circuit breaker.Earth (Ground)To prevent an electric shock, always earth (ground)the motor and inverter. For reduction of induction noisefrom the power line of the inverter, it is recommendedto wire the earth (ground) cable by returning it to theearth (ground) terminal of the inverter.5 6CompatibilityWarrantyInquiry

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!