12.07.2015 Views

AT Commands Manual - Teltonika

AT Commands Manual - Teltonika

AT Commands Manual - Teltonika

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>AT</strong> <strong>Commands</strong>User <strong>Manual</strong>− 1: indicator event reporting using result code +CIEV: ,. indicates the indicatororder number (as specified for +CIND) and is the new value indicator. Only the indicator eventswhich are not caused by +CIND shall be indicated by the TA to the TE.− 2: indicator event reporting using result code +CIEV: ,. All indicator events shall bedirected from TA to TE. may have the following values:− 0: TA buffer of unsolicited result codes defined within this command is cleared when 1...3 isentered− 1: TA buffer of unsolicited result codes defined within this command is flushed to the TE when 1...3 is entered (OK response shall be given before flushing the codes).5.9 Clock +CCLKCommand syntax<strong>AT</strong>+CCLK=<strong>AT</strong>+CCLK=”02/07/01,14:54:00”Read command<strong>AT</strong>+CCLK?Test command<strong>AT</strong>+CCLK=?DescriptionThis set command sets the real-time clock of the ME.OKorCME ERROR: +CCLK: “02/07/01,14:55:00”OKOK: string type value; format is “yy/MM/dd,hh:mm:ss+TZ”, wherein characters indicates year, month,day, hour, minutes, seconds. TZ: Time zone information represented by two digits. The time zone informationis optional; if it was entered it is always accepted, but the display of TZ for query contains this information (inupdated form) only if the network supports the time zone information.5.10 Alarm +CALACommand syntax<strong>AT</strong>+CALA=,,,,,<strong>AT</strong>+CALA=”02/07/01,14:56:00+04”,1,1,”Alarm”Read command<strong>AT</strong>+CALA?Test command<strong>AT</strong>+CALA=?DescriptionThis set command sets an alarm time in the MT. At expiration apredefined text is displayed. There can be an array of different types ofalarms, and each alarm may cause different text to be displayed in theMT display. If setting fails, a CME ERROR: is returned. Toset up a recurrent alarm for more days in the week, the parameter is used. When an alarm is timed out and executed, first thealarm actions are executed as display of provided text and e.g soundalarm, and second, the unsolicited alarm code +CALV: isdisplayed on DTE, even if the alarm was silent.OKorCME ERROR: +CALA: , , , , ,+CALA: , , , , ,[...] i.e. +CALA: ”02/07/01,14:56:00+04”,1,1,”Alarm”,0OK+CALA: (list of supported s),(list of supporteds),,,(list of supported ’s)OK: string type value; format is “yy/MM/dd,hh:mm:ss+tz”, wherein characters indicates year, month, day,hour, minutes, seconds and time zone.Note: if the parameter is used, the parameter must not contain a date. , , : integer type value indicating the index ofthe alarm; the maximum number of alarms is 3; if not indicated by user, default value 1 is assumed15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!