Quick-start Guide..53Flow Control <strong>System</strong>…Table 6-1. (cont.) Troubleshooting ChecklistSymptom Possible Cause Corrective Action<strong>System</strong> pressure (Pc) <strong>and</strong>/orpump pressures (Pa & Pb) showpressure even though the flow isoffPressure transducers zero offsetsare incorrectZero pressure transducers (Section4.5)No liquid out of waste line whenpurgingAir trap in the pumpInternal filters are pluggedLeak in the system prior to thepurge valvePrime the pump (Section 3.2).Contact <strong>Eksigent</strong> TechnologiesTechnical Support for assistance.Check all connections.Pump restrokes frequently- Pumphas reached end of stroke errormessage occursPump does not restroke at the endof a runAir trapped in the pumpPump remains on long enough toprompt a re-strokeCheck valve is leakingPump restroke delay is too shortPrime the pump (Section 3.2).Check the duration of time between restrokesto see if the pump re-strokewas appropriate.Contact <strong>Eksigent</strong> TechnologiesTechnical support for assistance.Contact <strong>Eksigent</strong> TechnologiesTechnical Support for assistance.Pump flushes out quickly but doesnot deliver ~600 µL per stroke.Leak in instrumentContact <strong>Eksigent</strong> TechnologiesTechnical Support for assistance.Purge output drips out slowly Internal filters are plugged Contact <strong>Eksigent</strong> TechnologiesTechnical Support for assistance.No flow rate with 100% powerindicated. <strong>System</strong> pressure (Pc)<strong>and</strong> pump pressures (Pa & Pb)are all lowNo air to system<strong>System</strong> not properly primed <strong>and</strong>flushedConnect 100 psi clean, dry air to theinstrument’s air inlet.Prime <strong>and</strong> flush system (Section 3.2).Inability to reach desired flow rateInternal filters are pluggedFlow rate set point too high forsystem back pressureAir pressure too lowContact local <strong>Eksigent</strong> TechnologiesTechnical Support to replace internalfilters.Reset flow rate to a lower level.Establish correct air pressure (100 psi).nanoLC Operator’s <strong>Manual</strong> 611-00012 Revision A1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!