YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Hunter</strong> e36 • AC Electric SystemsTroubleshootingProblem Possible Cause SolutionNo AC powerMain breaker(s) aft cabintripped or offShore power cord not connectedLoose or disconnected wireTurn breaker on or resetCheck cord, plug in if necessaryTighten connections. See your dealerNo power to AC devicesBreaker(s) at AC controlCenter tripped or offShore power cord not connectedLoose or disconnected wireTurn breaker on or resetCheck cord. Plug in if necessaryCheck cord. Plug in if necessaryTighten connections. See your dealerInadequate power to ACdevices(generator running)Electrical demand greaterthan generator outputSwitch off devicesand equipment not neededSwitch PARALLEL breaker off to reduce demandUse shore power AC line if availableContinuous tripping of mainbreakerCause of problem not correctedDetermine cause and correct problem before resettingbreakerSee your dealer if problem persistsGenerator will not start Battery discharged or dead Recharge or replace batteryNo power at AC outletsOutlet breaker in AC controlcenter OFFGround fault interruptertrippedSwitch breaker to ONReset button on outlet and test8.8