13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance Statement4.2.3 Storage SCP AE Specification4.2.3.1 SOP ClassesFor SOP Classes supported, please refer to “Table 1 - Network Services” Sections “Transfer” onpage 2.4.2.3.2 Association Policies4.2.3.2.1 GeneralThe <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM application will accept any number of verification or storage SOPclasses that are referred to above. There is no limit on the number of presentation contextsaccepted except for the DICOM limit. In the event that the <strong>Siemens</strong> DICOM application runs outof resources, it will reject the association request.When "trusted host functionality" is enabled <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go will only accept Associations fromknown hosts with a known AET. Hosts and AETs have to be entered in "Local Service" by a<strong>Siemens</strong> CSE.The default PDU size used will be 32 KB.4.2.3.2.2 Number of AssociationsThe <strong>Siemens</strong> <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM application is able to accept multiple associations at a time.It can handle up to 10 associations in parallel.The number of simultaneous DICOM associations can be configured via the Service-UI. Thedialog can be found in "Configuration / DICOM / General".4.2.3.2.3 Asynchronous NatureThe <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM software does not support asynchronous communication (multipleoutstanding transactions over a single association).4.2.3.2.4 Implementation Identifying InformationFor Implementation Identifying Information please refer to “Table 3 - Implementation IdentifyingInformation” in the “Conformance Statement Overview”.4.2.3.3 Association Initiation PolicyIf the result from a previously accepted Storage Commitment request is evaluated, the <strong>Artis</strong><strong>zee</strong>/<strong>zee</strong>go DICOM application attempts to initiate a new association for• DIMSE N-EVENT-REPORT for sending commitment result from a previous request.4.2.3.3.1 Activity - Return commitment resultWhen <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go Storage SCP AE received a Storage Commitment request it tries to sendthe response back on the same association. When the association is not open anymore it willinitiate an association to send the storage commitment response (N-EVENT-REPORT) to theSCU.4.2.3.3.1.1 Proposed Presentation Context© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 20 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!