13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance Statement4.2.8 Modality PPS SCU AE4.2.8.1 SOP ClassesFor SOP Classes supported, please refer to “Table 1 - Network Services” section „WorkflowManagement“ in the “Conformance Statement Overview”.4.2.8.2 Association Policies4.2.8.2.1 GeneralThe creation of MPPS Instance is done automatically by <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go whenever a patient isregistered for image acquisition through the Patient Registration dialog.Further updates on the MPPS data can be done interactively from the related MPPS userinterface. The MPPS “Complete” or “Discontinued” states can be set from user interface.The default PDU size used will be 32KB.4.2.8.2.2 Number of AssociationsThe <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM application initiates one association at a time to create or set theMPPS instance.4.2.8.2.3 Asynchronous NatureThe <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM software does not support asynchronous communication (multipleoutstanding transactions over a single association).4.2.8.2.4 Implementation Identifying InformationFor Implementation Identifying Information please refer to “Table 3 - Implementation IdentifyingInformation” in the “Conformance Statement Overview”.4.2.8.3 Association Initiation PolicyThe <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM application will notify a RIS (MPPS Manager) about the status of aprocedure while it is performed. It establishes an association by using the• N-CREATE DIMSE according to the CREATE Modality Performed Procedure Step SOPInstance operation or a• N-SET DIMSE to update the contents and state of the MPPS according to the SET ModalityPerformed Procedure Step Information operation.It is possible to configure multiple MPPS providers but only one can be active at a time. Theactive MPPS provider can be selected in the user settings.4.2.8.3.1 Activity - Patient registered4.2.8.3.1.1 Description and Sequencing of ActivityA patient is registered by the Patient Registration “Exam” action. From this event the trigger tocreate a MPPS Instance is derived. The related Instance is then immediately communicated tothe configured RIS system. An association is established and the MPPS Instance is sent.© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 52 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!