13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementThe affected SOP Instance UID received with N-CREATE-RSP message will be kept internallyand is used for later requests on the Basic Film Box (N-CREATE-RQ) and on the PresentationLUT (N-DELETE-RQ) - see below:Attribute Name Tag Source of Information(0000,1000) Affected SOP Instance UID of N-CREATE-RSPRequested SOP Instance UID (0000,1001)on Presentation LUTThe Presentation LUT SOP Class interprets the following status codes:Table 33 - Presentation LUT Status CodesService Status Meaning CodesSuccess Presentation LUT successfully created 0000WarningRequested MinDensity or MaxDensity outside ofprinter's operating range. The printer will use itsrespective minimum or maximum density valueinstead.B605Printer SOP ClassThe Printer SOP Class allows to monitor the status of the hardcopy printer in a synchronous andan asynchronous way.The SCU uses the mandatory N-EVENT Report DIMSE service to monitor the changes of theprinter status in an asynchronous way.The following returned information is supported:Table 34 - Used Printer N-EVENT Report attributesEvent-type Name Event Attributes Tag Usage SCUNormal 1Warning 2 Printer Status Info (2110,0020) UFailure 3 Printer Status Info (2110,0020) UU = User OptionTable 35 - Mandatory Printer N-GET-RSP, N-EVENT-REPORT-RQ attributesAttribute Name Tag Usage SCP Supported ValuesPrinter Status (2110,0010) M NORMAL, FAILURE, WARNINGPrinter Status Info (2110,0020) M See tables in Annex for details.M = MandatoryNote: For a detailed description on how <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go reacts on different printer status messages, please refer to theAnnex section “DICOM Print SCU - detailed status displays”.Printer Job SOP ClassThe Print Job SOP Class allows to monitor the execution of the print process.The <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM Print Management application supports the optional N-EVENT-REPORT DIMSE Service to receive the changes of the Print Job Status in an asynchronous way.It can receive Events from the Print SCP asynchronously:© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 42 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!