13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementTable 66 - (Private) Angio Acquisition Data AttributesAttribute Name Tag Owner Type NotesAcquisition TypeAcquisition ModeFoot Switch IndexAcquisition RoomCurrent Time ProductDoseSkin Dose PercentSkin Dose AccumulationSkin Dose RateCopper FilterMeasuring FieldTotal StepsDyna X-Ray InfoGamma InputGamma OutputSH_STPARAcquisition ZoomDyna Angulation StepDDO Value(0021,xx00)(0021,xx01)(0021,xx02)(0021,xx03)(0021,xx04)(0021,xx05)(0021,xx06)(0021,xx07)(0021,xx08)(0021,xx0A)(0021,xx0B)(0021,xx0E)(0021,xx0F)(0021,xx10)(0021,xx11)(0021,xx12)(0021,xx13)(0021,xx14)(0021,xx15)SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.03333Technical Type of Acquisitionperformed to get image result.Defined Terms are1 = fixed frame rate,2 = variable frame rate (manuallytriggered),3 = variable frame rate (timetriggered),4 = peri manual to head,10 = dynavision manual inject.,11 = dynavision automatic,14 = pulsed fluoro,15 = ECG triggered fluoro16 = scanning slow speed17 = scanning fast speedTechnical Mode of Acquisitionperformedto get image result.Defined Terms are:0 = no mode specified,1 = Digital Radiography,2 = DSA,3 = Peri-DSA,4 = DR stepping,5 = DR Dynavision (nat),6 = Dynavision (sub),7 = Card,9 = 3D Mode20 = Roadmap Fluoro,21 = Normal Fluoro,3 (uAs)3 (uGy/pulse)33 (mGy)33333333333Number of multi-frame imageswhich make up a Peri or DR-StepacquisitionMultiplicity of (4 * Number ofFrames).(kV value, uA value, ms, uAs value)Only with Dyna ImagesTechnical data-structure withGantry information.0 = Off, 1 = On.Not to be mixed up with digitalzoom from Viewing module.in 0.01deg / pulseOnly with rotational images© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 83 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!