13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementAttribute NameTagReturnKey UI IOD MPPSTypeReferenced Visit Sequence (universal SequenceMatch)(0008,1125) 3 ->Referenced SOP Class UID (0008,1150) 1C ->Referenced SOP Instance UID (0008,1155) 1C -Referenced Patient Alias Sequence (universalSequence Match)(0038,0004) 3 ->Referenced SOP Class UID (0008,1150) 1C ->Referenced SOP Instance UID (0008,1155) 1C -• The Worklist SCU interprets the following status codes:Table 43 - Status Codes "Update Worklist"Service Status Meaning Error Codes Related FieldsRefused Out of Resources A700 (0000,0902)FailedIdentifier does not match SOP Class(0000,0901)A900(0000,0902)Unable to process(0000,0901)Cxxx(0000,0902)Cancel Matching terminated due to Cancel request FE00 NoneSuccess Matching is complete - No final Identifier is supplied 0000 NonePendingMatches are continuing - Current Match is suppliedand any Optional Keys were supported in the samemanner as Required KeysMatches are continuing - Warning that one or moreOptional Keys were not supported for existence and/ormatching for this identifier4.2.7.3.2 Activity - Get Worklist4.2.7.3.2.1 Description and Sequencing of ActivityFF00FF01IdentifierIdentifierWith "Get Worklist" in the patient based Worklist Query dialog, the entered attributes are used toform a worklist request identifier. The response data is used to fill the Patient Registration dialog.The response data are additionally placed in the Scheduler DB.4.2.7.3.2.2 Proposed Presentation ContextThis Activity will propose the same Presentation Context as with “Update Worklist”. Please seerelated table in section 4.2.7.3.1.2.4.2.7.3.2.3 SOP Specific ConformanceThe <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM worklist SCU supports “narrow worklist queries” with all requiredsearch keys. The following tables describe the “narrow query” search keys that the SCUsupports.Table 44 - Patient based "narrow query" Search Key AttributesAttribute NameTagMatchingKey TypeQuery ValueScheduled Procedure StepScheduled Procedure Step Sequence (0040,0100) R>Scheduled Performing Physician’s Name (0040,0006) R input from UI or Requested ProcedureRequested Procedure ID (0040,1001) O input from UI or Imaging Service RequestAccession Number (0008,0050) O input from UI or Referring Physician’s Name (0008,0090) O input from UI or Visit Status© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 50 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!