13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementInformation ObjectDefinitionTable 56 - STD-GEN-xxx profile supported SOP ClassesSOP Class UIDX-Ray Angiographic Image 1.2.840.10008.5.1.4.1.1.12.1Comprehensive SR 1.2.840.10008.5.1.4.1.1.88.33X-Ray Radiation Dose SR 1.2.840.10008.5.1.4.1.1.88.67CSA Non-Image 1.3.12.2.1107.5.9.1Transfer Syntax UIDExplicit VR Little Endian1.2.840.10008.1.2.1JPEG Lossless Process 14 (selection value1) 1.2.840.10008.1.2.4.70Explicit VR Little Endian1.2.840.10008.1.2.1Explicit VR Little Endian1.2.840.10008.1.2.1Explicit VR Little Endian1.2.840.10008.1.2.15.2.1.2.2.1 Media Storage Application ProfileSee “Table 55 - Mapping of Application Profiles Supported” in section 5.2.1 for the ApplicationProfiles listed that invoke this Application Entity for the Import into Local Storage activity.5.2.1.3 Activity “Export to Local Archive Media”The DICOM Archive application acts as FSU (for media with existing DICOM file-set) or FSC(media not initialized) using the interchange option when requested to copy SOP Instances fromthe local storage to local Archive Medium.The DICOM Archive application will receive a list of SOP Instances to be copied to the localarchive medium. According to the state of the medium inserted (new medium, Medium withDICOM file-set) the validity of the SOP Instances according to the applicable profile is checked.Only valid SOP Instances are accepted.The DICOM Archive application will not finalize the medium.With the resizing feature of the <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM application, a copy of images in CardiacFormat (512x512, 8Bit) can be written onto medium.5.2.1.3.1.1 Media Storage Application ProfileSee “Table 55 - Mapping of Application Profiles Supported” in section 5.2.1 for the ApplicationProfiles listed that invoke this Application Entity for the Export to Local Archive Media activity.5.3 Augmented and Private Application Profilesnot applicable© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 65 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!