s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementAttribute Name Tag Owner Type NotesMedCom Header InfoMedCom HistoryInformationPMTF Information 1PMTF Information 2PMTF Information 3PMTF Information 4PMTF Information 5Application HeaderSequence>Application Header Type>Application Header ID>Application HeaderVersion>Application Header InfoWorkflow Control FlagsArchive Management FlagKeep OnlineArchive Management FlagDo Not ArchiveImage Location StatusEstimated Retrieve TimeData Size of RetrievedImagesSeries Workflow Status(0029,xx10)(0029,xx20)(0029,xx31)(0029,xx32)(0029,xx33)(0029,xx34)(0029,xx35)(0029,xx40)(0029,xx41)(0029,xx42)(0029,xx43)(0029,xx44)(0029,xx50)(0029,xx51)(0029,xx52)(0029,xx53)(0029,xx54)(0029,xx55)(0029,xx60)SIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADERSIEMENS MEDCOMHEADER233Manufacturer model dependentinformation.The value of the attribute MedComHeader Info (0029,xx10) can be buildup in each user defined format.MedCom defined Patient Registrationhistory information. See A.1.3.1.3 Transformation Information3 Transformation Information3 Transformation Information3 Transformation Information3 Transformation Information31CSequence of Application Header items.Zero or more items are possible.Application Header identificationcharacteristics.Required, if Sequence is sent.3 Identification of an application header3Version of CSA Series Header Info(0029,xx44) format.3 Application dependent information.3 Eight free definable flags.3333Flag to control remote archivemanagement system to keep the imagealways online (also when alreadyarchived).Enumerated Values:00 = remote control not required01 = keep image onlineFlag to control remote archivemanagement system not to archive therelated image.Enumerated Values:00 = remote control not required01 = don’t archive imageImage location status to controlretrieving.Defined Terms:ONLINE = retrieving has to be done asusual,NEARLINE = move request to SCPand delay according to value ofEstimated Retrieve Time (0029,xx54),OFFLINE = invoking a retrieveoperation initiates an operator request,INVALID = invoking a retrieveoperation would always result in anerror.Estimated retrieve time in seconds. Avalue less then zero (< 0) indicateslocation is OFFLINE or INVALID.3 Data size of images in MByte.38.5.2.1.1 MEDCOM History InformationThe value of the attribute MEDCOM History Information (0029,xx20) is defined in the followingway:© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 88 of 105
s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementTable 72 - MEDCOM History Information AttributesPart Name Type Bytes Notesheader>n ItemsIdentifier string 32 Always “CSA HISTORY”Version string 32 e.g. “V1.10”Class Name string 64Modification String string 10248.5.2.2 MEDCOM OOGThe table in this section contains private IOD Attributes that describe MEDCOM Object OrientedGraphics (OOG). This module is used whenever object graphics is drawn on the image and needto be stored as graphic object properties. Given the condition that the module contents was notremoved by other modalities, the graphic objects remain re-animatable if such an image wastransferred and is then retrieved back.Table 73 - MEDCOM OOG AttributesAttribute Name Tag Owner Type NotesCSA Series Header TypeCSA Series Header VersionCSA Series Header Info(0029,xx08)(0029,xx09)(0029,xx10)SIEMENS MEDCOMOOGSIEMENS MEDCOMOOGSIEMENS MEDCOMOOG133MEDCOM Object OrientedGraphics (OOG) identificationcharacteristics.Defined Terms:MEDCOM OOG 1MEDCOM OOG 2Version of MEDCOM OOG Info(0029,xx10) format.MEDCOM Object OrientedGraphics (OOG) data.The graphics objects are also fully encoded in the Image Overlay Plane for compatibility withother products, which do not support the MedCom OOG module. Any system not supporting theMedCom OOG module shall remove the OOG module and its contents when modifying the imageoverlay plane content.8.6 Private Transfer SyntaxesNo private Transfer Syntaxes are defined for or requested by <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go DICOM application.© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 89 of 105