13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementAttribute Name Tag ValueAcquisition Time (0008,0032) Time the acquisition of the original image was performedContent Time (0008,0033) Time this image was created (Store Reference image was performed)Series Number (0020,0011) Same Number as Acquisition Number. (Reference to original Image)Acquisition Number (0020,0012)Instance Number (0020,0013)Counts number of acquisitions. Refers to the acquisition number of theoriginal image where this image was derived from."100-based" counter for images. Indicates the creation order of StoreReference images within this seriesQuant Report images, derived from original images or Fluoro LIH, are identified by the followingattribute contents:Table 77 - Attributes for Identification of Quant Report ImagesAttribute Name Tag ValueImage Type (0008,0008)DERIVED\SECONDARY\SINGLE PLANE\SINGLE A\QUANTDERIVED\SECONDARY\SINGLE PLANE\SINGLE B\QUANTSeries Time (0008,0031) Time this Quant image was created (Quant was performed)Acquisition Time (0008,0032) Time the acquisition of the original image was performedContent Time (0008,0033) Time this Quant image was created (Quant was performed)Series Number (0020,0011) Same Number as Acquisition Number. (Reference to original Image)Acquisition Number (0020,0012)Counts number of acquisitions. Refers to the acquisition number of theoriginal image where this image was derived from.Instance Number (0020,0013) "1-based" counter for images. Quant Reports are stored in new series.EXAM PROTOCOL as XA image, created during transfer of X-Ray Radiation Dose SR, isidentified by the following attribute contents:Table 78 - Attributes for Identification of EXAM Protocol XA ImageAttribute Name Tag ValueImage Type (0008,0008) ORIGINAL\PRIMARY\SINGLE PLANE\SINGLE A\EXAM PROTOCOLSOP Class UID (0008,0016) 1.2.840.10008.5.1.4.1.1.12.1Series Time (0008,0031) Exam Protocol is allocated with Patient Registration.Acquisition Time (0008,0032) Time this protocol was created (i.e. transferred)Content Time (0008,0033) Time this protocol was created (i.e. transferred)Series Number (0020,0011) Fixed value of "999"Acquisition Number (0020,0012) Fixed value of "999"Instance Number (0020,0013) Fixed value of "999"8.7.2 The Sorting Algorithms of the <strong>Artis</strong> Viewer<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go has implemented sorting algorithms to display DICOM objects in the directoryoverview in a specific order. Sorting/Grouping in the Viewer Directory Overview occurs accordingthe following rules:1. Sort by Series Number2. If Series Number matches: Group on Series Number, Sort by Instance Number3. If Series Number and Instance Number each match: Group on Series Number, Sort byContent TimeIn the case, that the user has selected "Scenes + Ref Images" or "Scenes + Store Monitor", thereference images or the store monitor images follow directly the image they had been derivedfrom.© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 91 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!