13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance Statement• Try to import with ISO_IR 100. If ISO_IR 100 fails, convert each illegal character to a ’?’.There are now three categories of character sets which have to be differentiated because oftheir different encoding formats:• Conventional ISO character sets: ISO_IR 6, ISO 2022 IR 6, ISO_IR 100, etc. encoded in ISO 2022• ISO IR_192 encoded in UTF-8• GB18030 encoded in GB18030It is not possible to recognize the following mismatches automatically on receiving or importing:• An attribute value is encoded in ISO_IR 192 (0008,0005) contains a conventional ISOcharacter set as primary character set.• An attribute value is encoded in GB18030 (0008,0005) contains a conventional ISOcharacter set as primary character set.• An attribute value is encoded in ISO 2022 (0008,0005) contains ISO_IR 192.• An attribute value is encoded in ISO 2022 (0008,0005) contains GB18030An IOD that contains one of the above mentioned inconsistencies is not DICOM conform. Asthese kinds of inconsistencies cannot be recognized by the system, the IOD will not be rejectedbut the character data might not be displayed as intended.Older versions of <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go do not support the newly introduced character sets ISO_IR 192and GB18030 and their special encodings. That means, an IOD which contains one of these newcharacter sets in (0008,0005) will be rejected by an older <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go.7 SecurityThe <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go is supporting security by having the firewall of the underlying operatingsystem active. Besides the standard ports of the operating system, only the DICOM Port (104) isopened.When "trusted host functionality" is enabled, the <strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go only accepts DICOMcommunication from other AE if the related System is configured with its hostname, port andAET.© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 69 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!