13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementAttribute Name Tag Owner Type NotesDR Single Flag(0021,xx16)SIEMENS SMS-AX ACQ 1 = DR SINGLE, else single Frame31.0DR acquisitionSource to Isocenter(0021,xx17)SIEMENS SMS-AX ACQ1.03 (mm)ECG Index Array(0021,xx19)SIEMENS SMS-AX ACQ1.03FD Flag(0021,xx1A)SIEMENS SMS-AX ACQ1.03SH_ZOOM(0021,xx1B)SIEMENS SMS-AX ACQ1.03SH_COLPAR(0021,xx1C)SIEMENS SMS-AX ACQ Technical data-structure with31.0collimator information.K-Factor(0021,xx1D)SIEMENS SMS-AX ACQ1.03EVE(0021,xx1E)SIEMENS SMS-AX ACQ1.03Total Scene Time(0021,xx1F)SIEMENS SMS-AX ACQ1.03Restore Flag(0021,xx20)SIEMENS SMS-AX ACQ1.03Stand Movement Flag (0021,xx21)SIEMENS SMS-AX ACQ1.03 1 = movements during acquisitionFD Rows(0021,xx22)SIEMENS SMS-AX ACQ1.03 Acquisition matrix, rowsFD Columns(0021,xx23)SIEMENS SMS-AX ACQ1.03 Acquisition matrix, columnsTable Movement Flag (0021,xx24)SIEMENS SMS-AX ACQ 1 = for movements during31.0acquisitionIC Stent Flag(0021,xx27)SIEMENS SMS-AX ACQ1.03Gamma LUT Sequence (0021,xx28)SIEMENS SMS-AX ACQ1.03>Gamma LUT Descriptor (0021,xx40)SIEMENS SMS-AX ACQ1.03>Gamma LUT Type(0021,xx41)SIEMENS SMS-AX ACQ1.03>Gamma LUT Data(0021,xx42)SIEMENS SMS-AX ACQ1.033D Cardiac Phase Center (0021,xx2A)SIEMENS SMS-AX ACQ1.033D Cardiac Phase Width (0021,xx2B)SIEMENS SMS-AX ACQ1.03Organ Program Info(0021,xx30)SIEMENS SMS-AX ACQ Technical data-structure with organ31.0program informationmAs Modulation(0021,xx3B)SIEMENS SMS-AX ACQ only for cardiac triggered 3D31.0acquisition3D R-Peak Reference Time (0021,xx3C)SIEMENS SMS-AX ACQ one value per frame, only for31.0cardiac triggered 3D acquisitionECG Frame Time Vector (0021,xx3D)SIEMENS SMS-AX ACQ one value per frame, only for ECG31.0gated fluoro / acquisitionECG Start Time of Run (0021,xx3E)SIEMENS SMS-AX ACQ absolute time in sec (UTC), only for31.0ECG gated fluoro / acquisition3D Positioner Primary StartSIEMENS SMS-AX ACQ (deg)(0021,xx51)3Angle1.0Only with rotational images3D Positioner SecondarySIEMENS SMS-AX ACQ (deg)(0021,xx52)3Start Angle1.0Only with rotational imagesStand Position(0021,xx53)SIEMENS SMS-AX ACQ in 0.1 mm; x, y, z31.0Only with rotational imagesRotation Angle(0021,xx54)SIEMENS SMS-AX ACQ in 0.1 deg31.0Only with rotational imagesImage Rotation(0021,xx55)Rotation in relation to defaultpatient position0 = not rotated,SIEMENS SMS-AX ACQ3 1 = rotated in clockwise direction,1.02 = rotated in counterclockwisedirection,Only with rotational imagesTable CoordinatesIsocenter Table Position(0021,xx56)(0021,xx57)SIEMENS SMS-AX ACQ1.0SIEMENS SMS-AX ACQ1.03(mm); x, y, zOnly with rotational images3 in 0.1 mm; long, lat, height© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 84 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!