13.07.2015 Views

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementAttribute Name Tag ValueModality LUT Sequence (0028,3000) (if [0028,1040] = LOG)>LUT Descriptor (0028,3002), ,>Modality LUT Type (0028,3004) US>LUT data (0028,3006) Representative Frame Number (0028,6010) Mask Subtraction Sequence (0028,6100)>Mask Operation (0028,6101) AVG_SUB>Mask Frame Number (0028,6110) (only for AVG_SUB)Private Creator (0029,00xx) CARDIO-D.R. 1.0Attributes according to "8.5.1.1 Edge Enhancement Module"Private Creator (0029,00xx) CARDIO-D.R. 1.0Attributes according to "8.5.2.1 MEDCOM Header"Study ID Issuer (0032,0012) internal study identifierRequesting Physician (0032,1032) From RISRequesting Service (0032,1033) From RISRequested Procedure Description (0032,1060) From RISRequested Procedure Code Sequence (0032,1064) From RIS>Code Value (0008,0100) From RIS>Coding Scheme Designator (0008,0102) From RIS>Coding Scheme Version (0008,0103) From RIS>Code Meaning (0008,0104) From RISStudy Comments (0032,4000) Patient Registration inputSpecial Needs (0038,0050) From RISPatient State (0038,0500) From RISPerformed Procedure Step Start Date (0040,0244) supplied, even if MPPS SOP Class is not supportedPerformed Procedure Step Start Time (0040,0245) supplied, even if MPPS SOP Class is not supportedPerformed Procedure Step IDsupplied, even if MPPS SOP Class is not supported,(0040,0253) "XAyyyymmddhhmmss" is set with 1st ImageacquiredRequest Attributes Sequence (0040,0275)>Scheduled Procedure Step Description (0040,0007) From RIS>Scheduled Procedure Step ID (0040,0009) From RIS>Requested Procedure ID (0040,1001) From RIS or “Request ID” inputConfidentiality Constraint on Patient DataDescription(0040,3001) From RISPrivate Creator (0019,00xx) PMI Private Calibration Module Version 2.0Attributes according to "8.5.1.4 Angio Quantification Module"Curve Dimensions (5000,0005) 2Number of Points (5000,0010) Type of Data (5000,0020) ECGAxis UnitsDPPS\NONE(5000,0030)(DPPS = data points per second)Data Value Presentation (5000,0103) 0000hCurve Data Descriptor (5000,0110) 0\1Coordinate Start Value (5000,0112) 0Coordinate Step Value (5000,0114) Curve Data (5000,3000)Overlay RowsOverlay Columns(60xx,0010)(60xx,0011)Number of Frames in Overlay (60xx,0015) Overlay Description(60xx,0022)Overlay Type (60xx,0040) GOverlay Origin (60xx,0050) 1\1Image Frame Origin (60xx,0051) 1Overlay Bits Allocated (60xx,0100) 1 or 16© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 73 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!