Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

Artis zee/zeego VC14 - Siemens Healthcare

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

s<strong>Artis</strong> <strong>zee</strong>/<strong>zee</strong>go <strong>VC14</strong>DICOM Conformance StatementAttribute Name Tag ValueFocal Spot (0018,1190) (mm)Positioner Motion (0018,1500) STATIC | DYNAMICPositioner Primary Angle (0018,1510) (degrees); 0 with DYNAMICPositioner Secondary Angle (0018,1511) (degrees); 0 with DYNAMICPositioner Primary Angle Increment (0018,1520) Only with DYNAMIC (absolute values)Positioner Secondary Angle Increment (0018,1521) Only with DYNAMIC (absolute values)Shutter Shape (0018,1600) RECTANGULARShutter Left Vertical Edge (0018,1602) Shutter Right Vertical Edge (0018,1604) Shutter Upper Horizontal Edge (0018,1606) Shutter Lower Horizontal Edge (0018,1608) Collimator Shape (0018,1610) RECTANGULARCollimator Left Vertical Edge (0018,1702) Collimator Right Vertical Edge (0018,1704) Collimator Upper Horizontal Edge (0018,1706) Collimator Lower Horizontal Edge (0018,1708) Patient Position (0018,5100) Mandatory “Patient Position” inputDetector Description (0018,7006)Detector ID(0018,700A)Private Creator (0019,00xx) SIEMENS SMS-AX VIEW 1.0Attributes according to "8.5.1.2 Angio Viewing Module"Study Instance UID (0020,000D) From RIS or system generatedSeries Instance UID(0020,000E)Study ID (0020,0010) From RIS Requested Procedure ID or system createdSeries Number (0020,0011)Instance Number (0020,0013)Patient Orientation (0020,0020)calculated from "Patient Position" input and fromGantry coordinate data.Laterality (0020,0060) input via L or R marker annotation, else absentImages in Acquisition (0020,1002)Image Comments (0020,4000) Not encoded or "SM" or "REF"Private Creator (0021,00xx) SIEMENS SMS-AX ACQ 1.0Attributes according to "8.5.1.3 Angio Acquisition Data Module"Private Creator (0023,00xx) SIEMENS SMS-AX QUANT 1.0Attributes according to "8.5.1.4 Angio Quantification Module" if image was calibratedPrivate Creator (0025,00xx) SIEMENS SMS-AX ORIGINAL IMAGE INFO 1.0Attributes according to "8.5.1.5 Original Image Info Module"Samples per Pixel (0028,0002) 1Photometric Interpretation (0028,0004) MONOCHROME2Number of Frames (0028,0008)Frame Increment Pointer (0028,0009) (0018,1063) or (0018,1065) for variable frame rateRows (0028,0010) Up to 2480Columns (0028,0011) Up to 2480Bits Allocated (0028,0100) 8 | 16Bits Stored (0028,0101) 8 | 12 | 16High Bit (0028,0102) 7 | 11 | 15Pixel Representation (0028,0103) 0Pixel Intensity Relationship (0028,0103) LIN | LOG | DISPWindow Center (0028,1050) Window Width (0028,1051) VOI LUT Function (0028,1056)LINEAR | SIGMOIDnot set means linear windowingRecommended Viewing Mode (0028,1090) SUB | NATLossy Image Compression (0028,2110)© <strong>Siemens</strong> AG, <strong>Healthcare</strong> Sector 2009 Rev. 08 Page 72 of 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!