Position control by vector controlParameterNumber481482483484485486487488489490491492493NameNinth position feedamount lower 4 digitsNinth position feedamount upper 4 digitsTenth position feedamount lower 4 digitsTenth position feedamount upper 4 digitsEleventh position feedamount lower 4 digitsEleventh position feedamount upper 4 digitsTwelfth position feedamount lower 4 digitsTwelfth position feedamount upper 4 digitsThirteenth position feedamount lower 4 digitsThirteenth position feedamount upper 4 digitsFourteenth position feedamount lower 4 digitsFourteenth position feedamount upper 4 digitsFifteenth position feedamount lower 4 digitsInitial ValueSettingRange0 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 99990 0 to 9999Fifteenth position feed4940 0 to 9999amount upper 4 digitsThe above parameters can be set when the <strong>FR</strong>-A7AP (option) is mounted.Selection Method(OFF: ×, ON: ◦)REX RH RM RLPosition FeedFrequency◦ × × ◦ 9 Speed (Pr. 233)◦ × ◦ × 10 speed (Pr. 234)◦ × ◦ ◦ 11 speed (Pr. 235)◦ ◦ × × 12 speed (Pr. 236)◦ ◦ × ◦ 13 speed (Pr. 237)◦ ◦ ◦ × 14 speed (Pr. 238)◦ ◦ ◦ ◦ 15 speed (Pr. 239)118