FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2WIRINGConnection of motor with encoder (vector control)(3) Switches of the <strong>FR</strong>-A7AP• Encoder specification selection switch (SW1)Select either differential line driver or complementaryIt is initially set to the differential line driver. Switch its position accordingto output circuit.Differential linedriver (initial status)SW1ON1234SW2SW3ON12<strong>FR</strong>-A7APComplementary• Terminating resistor selection switch (SW2)Select ON/OFF of the internal terminating resistor. Set the switch to ON(initial status) when an encoder output type is differential line driver andset to OFF when complementary.ON : with internal terminating resistor (initial status)OFF : without internal terminating resistorInternal terminatingresistor-ON(initial status)SW1ON1234SW2SW3ON12<strong>FR</strong>-A7APREMARKS· Set all swithces to the same setting (ON/OFF).· If the encoder output type is differential line driver, set the terminating resistorswitch to the "OFF" position when sharing the same encoder with other unit (NC(numerical controller), etc) or a terminating resistor is connected to other unit.Internal terminating resistor-OFF• Motor used and switch settingMotorMitsubishi standard motor with encoderMitsubishi high efficiency motor withencoderEncoder SpecificationSelection Switch (SW1)Terminating ResistorSelection Switch (SW2)PowerSpecifications *2SF-JR Differential ON 5VSF-HR Differential ON 5VOthers *1 *1 *1SF-JRCA Differential ON 5VMitsubishi constant-torque motor withSF-HRCA Differential ON 5VencoderOthers *1 *1 *1Vector control dedicated motor SF-V5RU Complimentary OFF 12VOther manufacturer motor with encoder – *1 *1 *1*1 Set according to the motor (encoder) used.*2 Choose a power supply (5V/12V/15V/24V) for encoder according to the encoder used.CAUTIONSW3 switch is for manufacturer setting. Do not change the setting.• Encoder specificationItem Encoder for SF-JR/HR/JRCA/HRCA Encoder for SF-V5RUResolution 1024 Pulse/Rev 2048 Pulse/RevPower supplyvoltage5VDC±10%12VDC±10%Currentconsumption150mA150mAOutput signal formA, B phases (90° phase shift)A, B phases (90° phase shift)Z phase: 1 pulse/revZ phase: 1 pulse/revOutput circuit Differential line driver 74LS113 equivalent ComplimentaryOutput voltageH level: 2.4V or moreL level: 0.5V or lessCAUTIONEncoder with resolution of 1000 to 4096 pulse/rev is recommended.H level: "Power supply for encoder-3V" or moreL level: 3V or less31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!