4PARAMETERSParameter copy and parameter verificationappears...Why?appears...Why?Parameter read error. Perform operation from step 3 again.Parameter write error. Perform operation from step 8 again.4.30.2 Parameter verificationWhether same parameter values are set in other inverters or not can be checked.Operation1.Replace the operation panel on theinverter to be verified.• Replace it during a stop.Display2.Screen at powering onThe monitor display appears.3.Press to choose the parametersetting mode.The parameternumber readpreviously appears.4.Turn until (parameter copy)appears.5.Press to read the currently setvalue." "(initial value) appears.6.Turn to change it to the set value" "(parameter copy verification mode).7.Press to read the parameter settingof the verified inverter to the operation panel.Flickers for about 30s• If different parameters exist, differentparameter numbers and flicker.• Hold down to verify.FlickeringREMARKS8.It there is no difference, " " and " "flicker to complete verification.When the copy destination inverter is not the <strong>FR</strong>-<strong>A701</strong> series, "model error (Flicker ··· Parameter verification complete!!)" is displayed.flickers ... Why?Set frequencies, etc. may be different. Check set frequencies.367