13.07.2015 Views

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4PARAMETERSMonitor display and monitor output signalTypes of MonitorRunning speed 1(r/min) 6 *1 6The valueconvertedwith the Pr.37 valuefrom Pr. 55Motor torque 0.1% 7 *1 7 Pr. 866Converter outputvoltageElectronic thermalrelay function loadfactorOutput currentpeak valueConverter outputvoltage peak value0.1V 8 *1 80.1% 10 *1 10 100%0.01A 11 *1 11 Pr. 560.1V 12 *1 12Input power 0.01kW 13 *1 13Output power 0.01kW 14 *1 14200V class:400V400V class:800V200V class:400V400V class:800VRatedinverterpower × 2Ratedinverterpower × 2Displays the motor speed(The display differs depending on the Pr. 37and Pr. 144 settings. The running speed isthe actual speed by the encoder signalduring encoder feedback control and vectorcontrol. For details, refer to page 226.)Displays the motor torque in percentage on theassumption that the rated motor torque is 100%(0% is displayed during V/F control)Displays the DC bus voltage value.Displays the motor thermal cumulative valueon the assumption that the thermal operationlevel is 100%.Retains the peak value of the output currentmonitor and displays (clears at every start)Retains the peak value of the DC busvoltage value and displays (clears at everystart)Displays power on the inverter input sideDisplays power on the inverter output sideLoad meter 0.1% 17 17 Pr. 866Displays the torque current in % on theassumption that the Pr. 56 setting is 100%(displayed on the assumption that ratedmotor torque is 100% during sensorlessvector and vector control)Motor excitationcurrent0.01A 18 18 Pr. 56 Displays the excitation current of the motorPosition pulse *2 ⎯ 19 × ⎯Displays the number of pulses per rotation ofthe motor when orientation control is validCumulativeenergization time *4Reference voltageoutput1h 20 × ⎯⎯ ⎯ 21 ⎯Orientation status *2 1 22 × ⎯Actual operationtime *4, *51h 23 × ⎯Motor load factor 0.1% 24 24 200%Cumulative power *7 0.01kWh *6 25 × ⎯Torque command 0.1% 32 32 Pr. 866Torque currentcommandIncrementsPr. 52 SettingDU LEDPU mainmonitorPr. 54 (FM)Pr. 158 (AM)SettingDisplays the cumulative energization timesince the inverter shipment.You can check the numbers of the monitorvalue exceeded 65535h with Pr. 563.Terminal FM:1440 pulse/s is output when Pr. 291 = 0, 1.50k pulse/s is output when Pr. 291 ≠ 0, 1.Terminal AM: 10V is outputDisplays only when orientation control isvalid(Refer to page 195)Displays the cumulative inverter runningtime.You can check the numbers of the monitorvalue exceeded 65535h with Pr. 564.Use Pr. 171 to clear the value. (Refer to page232)Displays the output current value in % on theassumption that the rated inverter currentvalue is 100%.Monitor value = output current monitor value/rated inverter current × 100 [%]Displays the cumulative power amountaccording to the output power monitor.Use Pr. 170 to clear the value. (Refer to page232)Displays torque command value obtainedfrom vector control0.1% 33 33 Pr. 866 Displays torque current command valueMotor output 0.01kW 34 34Full-scaleValue of theTerminal FMand AMRated motorcapacityDescriptionMultiplies the motor speed by the then outputtorque and displays the machine output ofthe motor shaft end229

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!