13.07.2015 Views

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4PARAMETERSCommunication operation and setting•List of calibration parametersParameterC2(902)C3(902)125(903)C4(903)C5(904)C6(904)126(905)C7(905)C12(917)NameTerminal 2 frequencysetting bias frequencyTerminal 2 frequencysetting biasTerminal 2 frequencysetting gain frquencyTerminal 2 frequencysetting gainTerminal 4 frequencysetting bias frequencyTerminal 4 frequencysetting biasTerminal 4 frequencysetting gain frequencyTerminal 4 frequencysetting gainTerminal 1 biasfrequency (speed)InstructioncodeReadWriteExtended5E DE 15E DE 15F DF 15F DF 160 E0 160 E0 161 E1 161 E1 111 91 9ParameterC13(917)C14(918)C15(918)C16(919)C17(919)C18(920)C19(920)C38(932)NameTerminal 1 biasfrequency (speed)Terminal 1 gainfrequency (speed)Terminal 1 gain(speed)Terminal 1 biascommand (torque/magnetic flux)Terminal 1 bias(torque/magnetic flux)Terminal 1 gaincommand (torque/magnetic flux)Terminal 1 gain(torque/magnetic flux)Terminal 4 biascommand (torque/magnetic flux)InstructioncodeReadWriteExtended11 91 912 92 912 92 913 93 913 93 914 94 914 94 920 A0 9ParameterC39(932)C40(933)C41(933)NameTerminal 4 bias(torque/magnetic flux)Terminal 4 gaincommand (torque/magnetic flux)Terminal 4 gain(torque/magnetic flux)InstructioncodeReadWriteExtended20 A0 921 A1 921 A1 9[Special monitor selection No.]Refer to page 228 for details of the monitor description.Data Description IncrementsH01 Output frequency 0.01HzH02 Output current 0.01AH03 Output voltage 0.1VH05 Frequency setting 0.01HzH06 Running speed1r/minH07 Motor torque 0.1%H08 Converter output voltage 0.1VElectronic thermal relayH0Afunction load factor0.1%Output current peakH0BvalueConverter output voltageH0Cpeak valueH0D Input powerH0E Output powerH0F Input terminal status *10.01A/0.1A *10.1V0.01kW0.01kW⎯Data Description IncrementsH10 Output terminal status *2 ⎯H11 Load meter 0.1%H12 Motor excitation current 0.01AH13 Position pulse⎯Cumulative energizationH14time1hH16 Orientation status⎯H17 Actual operation time 1hH18 Motor load factor 0.1%H19 Cumulative power 1kWhH20 Torque command 0.1%H21 Torque current command 0.1%H22 Motor output0.01kWH23 Feedback pulse⎯H32 Power saving effect VariableH33 Cumulative saving power VariableData Description IncrementsH34 PID set point 0.1%H35 PID measured value 0.1%H36 PID deviation value 0.1%Option input terminalH3Astatus1 *3⎯Option input terminalH3Bstatus2 *4⎯Option output terminalH3Cstatus *5⎯*1 Input terminal monitor detailsb15b0⎯ ⎯ ⎯ ⎯ CS RES STOP MRS JOG RH RM RL RT AU STR STF*2 Output terminal monitor detailsb15b0⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ABC2 ABC1 FU OL IPF SU RUN*3 Details of option input terminal monitor 1 (input terminal status of <strong>FR</strong>-A7AX)-all terminals are off when an option is not fittedb15b0X15 X14 X13 X12 X11 X10 X9 X8 X7 X6 X5 X4 X3 X2 X1 X0*4 Details of option input terminal monitor 2 (input terminal status of <strong>FR</strong>-A7AX)-all terminals are off when an option is not fittedb15b0⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ DY*5 Details of option output terminal monitor (output terminal status of <strong>FR</strong>-A7AY/A7AR)-all terminals are off when an option is not fittedb15b0⎯ ⎯ ⎯ ⎯ ⎯ ⎯ RA3 RA2 RA1 Y6 Y5 Y4 Y3 Y2 Y1 Y0313

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!