Monitor display and monitor output signal4.16.2 DU/PU, FM, AM terminal monitor display selection (Pr. 52, Pr. 54, Pr. 158, Pr. 170,Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)The monitor to be displayed on the main screen of the operation panel (<strong>FR</strong>-DU07)/parameter unit (<strong>FR</strong>-PU04/<strong>FR</strong>-PU07) can be selected.In addition, signals to be output from the terminal FM (pulse train output) and AM (analog voltage output) can beselected.ParameterNumber52*54*158*(1) Monitor description list (Pr. 52)Name Initial Value Setting Range DescriptionDU/PU main display dataselectionFM terminal functionselectionAM terminal functionselection0(outputfrequency)1(outputfrequency)170 Watt-hour meter clear 99990, 5 to 8, 10 to14, 17 to 20, 22to 25,32 to 35, 50 to57, 1001 to 3, 5 to 8, 10to 14, 17, 18, 21,24, 32 to 34, 50,52, 53Select the monitor to be displayed on theoperation panel and parameter unit.Refer to the following table for monitor description.Select the monitor output to terminal FM.Select the monitor output to terminal AM.0 Set "0" to clear the watt-hour meter monitor.⋅ Set the monitor to be displayed on the operation panel (<strong>FR</strong>-DU07) and parameter unit (<strong>FR</strong>-PU04/<strong>FR</strong>-PU07) in Pr.52 DU/PU main display data selection.⋅ Set the monitor to be output to the terminal FM (pulse train output) in Pr. 54 FM terminal function selection.⋅ Set the monitor to be output to the terminal AM (analog voltage output (0 to 10VDC voltage output)) in Pr. 158 AMterminal function selection.⋅ Refer to the following table and set the monitor to be displayed. (The signals marked × cannot be selected formonitoring)109999171 Operation hour meter clear 9999 0, 9999268*563564891Monitor decimal digitsselectionEnergization timecarrying-over timesOperating time carryingovertimesCumulative power monitordigit shifted times9999009999Set the maximum value when monitoring fromcommunication to 0 to 9999kWh.Set the maximum value when monitoring fromcommunication to 0 to 65535kWh.Set "0" to clear the operation time monitor.Setting "9999" has no effect.0 Displayed as integral value1 Displayed in 0.1 increments9999 No function0 to 65535(reading only)0 to 65535(reading only)0 to 49999Displays the numbers of cumulative energizationtime monitor exceeded 65535h. Reading onlyDisplays the numbers of operation time monitorexceeded 65535h. Reading onlySet the number of times to shift the cumulativepower monitor digit.Clamps the monitor value at maximum.No shiftClears the monitor value when it exceeds themaximum value.* The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set inPr. 77 Parameter write selection.Types of Monitor IncrementsPr. 52 SettingFull-scalePr. 54 (FM)Value of thePU main Pr. 158 (AM)DU LEDTerminal FMmonitor Settingand AMDescriptionOutput frequency 0.01Hz 0/100 1 Pr. 55 Displays the inverter output frequency.Output current 0.01A 0/100 2 Pr. 56Displays the inverter output current effectivevalue.Output voltage 0.1V 0/100 3200V class:400V400V class:Displays the inverter output voltage.800VAlarm display ⎯ 0/100 × ⎯ Displays 8 past alarms individually.Frequency setting 0.01Hz 5 *1 5 Pr. 55 Displays the set frequency.228

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!