4PARAMETERSMonitor display and monitor output signal⋅ To display the machine speed, set in Pr. 37 the machine speed for operation with frequency set in Pr. 505.For example, when Pr. 505 = "60Hz" and Pr. 37 = "1000", "1000" is displayed on the running speed monitor when therunning frequency is 60Hz. When running frequency is 30Hz, "500" is displayed.⋅ When displaying the motor speed, set the number of motor poles (2, 4, 6, 8, 10) or number of motor poles + 100(102, 104, 106, 108, 110) in Pr. 144.⋅ The Pr. 144 setting is automatically changed if the number of motor poles is set in Pr. 81 Number of motor poles. The Pr.81 setting is not automatically changed even if the setting of Pr. 144 is changed.Example 1) When the initial setting of Pr. 81 is changed to "2" or "12", the Pr. 144 setting changes from "4" to "2".Example 2) When Pr. 144 = "104", setting "2" in Pr. 81 changes the Pr. 144 setting from "104" to "102".⋅ When "1, or 11" is set in Pr. 811, the setting increments of speed setting from the PU, speed setting from RS-485communication or communication options (other than <strong>FR</strong>-A7ND, <strong>FR</strong>-A7NL) and running speed monitor is 0.1r/min.⋅ When both Pr. 37 and Pr. 144 have been set, their priorities are as given below.Pr. 144, 102 to 110 > Pr. 37, 1 to 9998 > Pr. 144, 2 to 10⋅ When the running speed monitor is selected, each monitor and setting are determined by the combination of Pr. 37and Pr. 144 as listed below. (The units within the thick frame are the initial values.)Pr. 37Setting0(initialvalue)Pr. 144SettingOutput FrequencyMonitorSet FrequencyMonitorRunning SpeedMonitorFrequency SettingParameter Setting0 Hz Hz r/min *1 Hz2 to 10 Hz Hz r/min *1 Hz102 to 110 r/min *1 r/min *1 r/min *1 r/min *10 Hz Hz Machine speed *1 Hz1 to 9998 2 to 10 Machine speed *1 Machine speed *1 Machine speed *1 Machine speed *1102 to 110 Hz Hz r/min *1 Hz*1 Motor speed r/min conversion formula............ frequency × 120/number of motor poles (Pr. 144)Machine speed conversion formula................... Pr. 37 × frequency/Pr. 505For Pr. 144 in the above formula, the value is "Pr. 144 - 100" when "102 to 110" is set in Pr. 144 and the value is "4" when Pr. 37 = 0 and Pr. 144 = 0.*2 Hz is in 0.01Hz increments, machine speed is in 1 increments, and r/min is in 1r/min increments (depending on Pr. 811 ).*3 Pr. 505 is always set as frequency (Hz).⋅⋅⋅⋅⋅⋅⋅CAUTIONUnder V/F control, the output frequency of the inverter is displayed in terms of synchronous speed, and therefore, displayedvalue = actual speed + motor slip. This display changes to the actual speed (estimated value calculated based on the motorslip) when the advanced magnetic flux vector control or real sensorless vector control is selected, and actual speed from theencoder is displayed when encoder feed back control or vector control is performed.When the running speed display is selected at the setting of Pr. 37 = "0" and Pr. 144 = "0", the monitor display is provided on theassumption that the number of motor poles is 4. (1800r/min is displayed at 60Hz)Refer to Pr. 52 when you want to change the PU main monitor (PU main display).Since the panel display of the operation panel (<strong>FR</strong>-DU07) is 4 digits in length, the monitor value of more than "9999" isdisplayed "----".After setting the running speed in 0.1r/min increments (Pr. 811 = "1, 11"), changing the setting increments to 1r/min increments(Pr. 811 = "0, 10") changes the speed resolution from 0.1r/min to 0.3r/min (four poles), which may round down 0.1r/minincrements.When the machine speed is displayed on the <strong>FR</strong>-PU04/<strong>FR</strong>-PU07, do not change the speed by using an up/down key in thestate where the set speed exceeding 65535 is displayed. The set speed may become arbitrary value.When an optional <strong>FR</strong>-A7ND or <strong>FR</strong>-A7NL card is mounted, frequency is displayed regardless of Pr. 37 and Pr. 144 setting.CAUTIONMake sure that the settings of the running speed and number of motor poles are correct. Otherwise, the motormight run at extremely high speed, damaging the machine.♦ Parameters referred to ♦Pr. 1 Maximum frequency Refer to page 140Pr. 52 DU/PU main display data selection Refer to page 228Pr. 80 Motor capacity, Pr. 81 Number of motor poles Refer to page 131Pr. 800 Control method selection Refer to page 75Pr. 811 Set resolution switchover Refer to page 83227

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!