Parameter500NameInstructionCode * 1ReadWriteExtendedV/FControlControl Mode-based Correspondence Table *2AdvancedmagneticfluxvectorcontrolSpeedcontrolVector controlTorquecontrolPositioncontrolReal sensorlessvector controlCommunication errorexecution waiting time 00 80 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦SpeedcontrolTorquecontrolParameter Copy *3Parameter Clear *3All Parameter Clear *3501Communication erroroccurrence count display 01 81 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ × ◦ ◦502Stop mode selection atcommunication error 02 82 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦503 Maintenance timer 03 83 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ × × ×504Maintenance timer alarmoutput set time04 84 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ × ◦505 Speed setting reference 05 85 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦516S-pattern time at a start ofacceleration10 90 5 ◦ ◦ ◦ ◦ × ◦ ◦ ◦ ◦ ◦517S-pattern time at acompletion of acceleration11 91 5 ◦ ◦ ◦ ◦ × ◦ ◦ ◦ ◦ ◦518S-pattern time at a start ofdeceleraiton12 92 5 ◦ ◦ ◦ ◦ × ◦ ◦ ◦ ◦ ◦519S-pattern time at acompletion of deceleraiton13 93 5 ◦ ◦ ◦ ◦ × ◦ ◦ ◦ ◦ ◦539Modbus-RTUcommunication check time 27 A7 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ *5 ◦ *5interval541Frequency command signselection (CC-Link)29 A9 5 ◦ ◦ ◦ × × ◦ × ◦ ◦ *5 ◦ *5542Communication stationnumber (CC-Link)2A AA 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ *5 ◦ *5543 Baud rate (CC-Link) 2B AB 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ *5 ◦ *5544547548CC-Link extendedsettingParameter for manufacturer setting. Do not set.2C AC 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ *5 ◦ *5549 Protocol selection 31 B1 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ *5 ◦ *5550NET mode operationcommand source selection32 B2 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ *5 ◦ *5551PU mode operationcommand source selection33 B3 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ *5 ◦ *5555 Current average time 37 B7 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦556 Data output mask time 38 B8 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦557Current average valuemonitor signal output39 B9 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦ ◦reference current563Energization time carryingovertimes3F BF 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ × × ×564Operating time carryingovertimes40 C0 5 ◦ ◦ ◦ ◦ ◦ ◦ ◦ × × ×569Second motor speed controlgain45 C5 5 × ◦ × × × × × ◦ × ◦571 Holding time at a start 47 C7 5 ◦ ◦ ◦ ◦ × ◦ ◦ ◦ ◦ ◦574Second motor online autotuning4A CA 5 × ◦ × × × ◦ ◦ ◦ ◦ ◦575Output interruption detectiontime4B CB 5 ◦ ◦ ◦ × × ◦ × ◦ ◦ ◦576Output interruption detectionlevel4C CC 5 ◦ ◦ ◦ × × ◦ × ◦ ◦ ◦435

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!