Function assignment of external terminal and control4.15.6 Output terminal function selection (Pr. 190 to Pr. 196)You can change the functions of the open collector output terminal and relay output terminal.ParameterNumber190191192193194195196NameRUN terminalfunction selectionSU terminal functionselectionIPF terminal functionselectionOL terminal functionselectionFU terminal functionselectionABC1 terminalfunction selectionABC2 terminalfunction selectionOpencollectoroutputterminalRelayoutputterminalInitialValueInitial Signal0 RUN (inverter running)1 SU (up to frequency)2IPF (instantaneous powerfailure, undervoltage)3 OL (overload alarm)4FU (output frequencydetection)99 ALM (fault output)9999 No functionSetting Range0 to 6, 8, 10 to 20, 25 to 28, 30 to36, 39, 41 to 47, 64, 70, 84, 90 to99, 100 to 106, 108, 110 to 116,120, 125 to 128, 130 to 136, 139,141 to 147, 164, 170, 184, 190 to199, 99990 to 6, 8, 10 to 20, 25 to 28, 30 to36, 39, 41 to 47, 64, 70, 84, 85, 90,91, 94 to 99, 100 to 106, 108, 110to 116, 120, 125 to 128, 130 to136, 139, 141 to 147, 164, 170,184, 190, 191, 194 to 199, 9999(1) Output signal list⋅ You can set the functions of the output terminals.⋅ Refer to the following table and set the parameters: (0 to 99: Positive logic, 100 to 199: Negative logic)PositiveLogicSettingNegativeLogicSignalNameFunction0 100 RUN Inverter running1 101 SU Up to frequency *12 102 IPFInstantaneous powerfailure/undervoltage3 103 OL Overload alarm4 104 FU5 105 FU26 106 FU38 108 THPOutput frequencydetectionSecond outputfrequency detectionThird output frequencydetectionElectronic thermalrelay function prealarmOperationOutput during operation when the inverteroutput frequency rises to or above Pr. 13Starting frequency.Output when the output frequency is reachedto the set frequency. *3Output at occurrence of an instantaneouspower failure or when undervoltage protectionis activated.Output while stall prevention function isactivated.Output when the output frequency reachesthe frequency set in Pr. 42 (Pr. 43 for reverserotation). *3Output when the output frequency reachesthe frequency set in Pr. 50. *3Output when the output frequency reachesthe frequency set in Pr. 116. *3Output when the electronic thermal relayfunction cumulative value reaches 85% of thetrip level.(Electronic thermal relay function protection(E.THT/E.THM) activates, when the valuereached 100%.)RelatedParametersRefer toPage⎯ 217Pr. 41 221Pr. 57 239Pr. 22, Pr. 23,Pr. 66, Pr. 148,Pr. 149, Pr. 154135Pr. 42, Pr. 43 221Pr. 50 221Pr. 116 221Pr. 9 16710 110 PU PU operation modeOutput when the PU operation mode isselected.Pr. 79 283Output when the inverter power is turned on,11 111 RYInverter operation then output after reset process is completedready(when the inverter can be started by switching⎯ 217the start signal on or while it is running).12 112 Y12Output when the output current is higher thanOutput currentthe Pr. 150 setting for longer than the time set Pr. 150, Pr. 151detectionin Pr. 151.223Output when the output power is lower than13 113 Y13 Zero current detection the Pr. 152 setting for longer than the time set Pr. 152, Pr. 153in Pr. 153.223214

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!