13.07.2015 Views

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4PARAMETERSParameter listFunctionParameter Name Setting Range⎯ 168⎯ 169Parameter for manufacturer setting. Do not set.MinimumSettingIncrementsInitial ValueRefertoPageCustomerSettingCumulative monitorclearUser groupInput terminal function assignmentOutput terminal function assignment170 Watt-hour meter clear 0, 10, 9999 1 9999 228171 Operation hour meter clear 0, 9999 1 9999 228172User group registered display/batchclear9999, (0 to 16) 1 0 281173 User group registration 0 to 999, 9999 1 9999 281174 User group clear 0 to 999, 9999 1 9999 2810 to 9, 12 to 20, 22 to 28,178 STF terminal function selection 42 to 44, 60, 62, 64 to 69, 1 60 20674, 99990 to 9, 12 to 20, 22 to 28,179 STR terminal function selection 42 to 44, 61, 62, 64 to 69, 1 61 20674, 9999180 RL terminal function selection1 0 206181 RM terminal function selection 0 to 9, 12 to 20, 22 to 28, 1 1 20642 to 44, 62, 64 to 69, 74,182 RH terminal function selection 99991 2 206183 RT terminal function selection 1 3 2060 to 9, 12 to 20, 22 to 28,184 AU terminal function selection42 to 44, 62 to 69, 74,1 4 2069999185 JOG terminal function selection1 5 206186 CS terminal function selection0 to 9, 12 to 20, 22 to 28,1 6 206187 MRS terminal function selection 42 to 44, 62, 64 to 69, 74, 1 24 206188 STOP terminal function selection99991 25 206189 RES terminal function selection 1 62 206190 RUN terminal function selection 0 to 6, 8, 10 to 20, 25 to 1 0 214191 SU terminal function selection28, 30 to 36, 39, 41 to 47,64, 70, 84, 90 to 99,1 1 214192 IPF terminal function selection 100 to 106, 108, 110 to 1 2 214193 OL terminal function selection116, 120, 125 to 128, 130to 136, 139, 141 to 147, 1 3 214194 FU terminal function selection164, 170, 184, 190 to199, 99991 4 2140 to 6, 8, 10 to 20, 25 to195 ABC1 terminal function selection28, 30 to 36, 39, 41 to 47,64, 70, 84, 90, 91, 94 to1 99 21499, 100 to 106, 108, 110to 116, 120, 125 to 128,196 ABC2 terminal function selection130 to 136, 139, 141 to147, 164, 170, 184, 190,1 9999 214191, 194 to 199, 9999Parameter ListMulti-speedsetting232 to 239Multi-speed setting (8 speed to 15speed)0 to 400Hz, 9999 0.01Hz 9999 148⎯ 240 Soft-PWM operation selection 0, 1 1 1 257⎯ 241 Analog input display unit switchover 0, 1 1 0 267⎯ 242Terminal 1 added compensationamount (terminal 2)0 to 100% 0.1% 100% 263⎯ 243Terminal 1 added compensationamount (terminal 4)0 to 100% 0.1% 75% 263⎯ 244 Cooling fan operation selection 0, 1 1 1 35359

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!