FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

FR-A701 INSTRUCTION MANUAL (Applied) - Automation Systems ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Selection and protection of a motorParameterNumber458459460461462463684Second motor constant(R1)Second motor constant(R2)Second motor constant(L1)Second motor constant(L2)Second motor constant(X)Second motor autotuning setting/statusTuning data unitswitchover9999 0 to 50Ω, 99999999 0 to 50Ω, 9999999999999999859 Torque current 9999860NameSecond motor torquecurrentInitialValue009999Setting Range0 to 50Ω(0 to 1000mH),99990 to 50Ω(0 to 1000mH),99990 to 500Ω(0 to 100%), 9999Tuning data of the second motor(The value measured by offline auto tuning isautomatically set.)9999: Use the Mitsubishi motor (SF-JR, SF-HR,SF-JRCA, SF-HRCA, SF-V5RU (1500r/min series))constants0 Second motor auto tuning is not performed1101Offline auto tuning is performed without secondmotor runningOffline auto tuning is performed with second motorrunning0 Internal data converted value1 Displayed in "A, Ω, mH, %"0 to 500A99990 to 500A9999DescriptionTuning data(The value measured by offline auto tuning isautomatically set.)Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500r/min series))constantsTuning data of the second motor(The value measured by offline auto tuning isautomatically set.)Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500r/min series))constantsPOINT· This function is made valid only when a value other than "9999" is set in Pr. 80 and Pr. 81 and advanced magneticflux vector control, real sensorless vector control or vector control is selected.· You can copy the offline auto tuning data (motor constants) to another inverter with the PU (<strong>FR</strong>-DU07/<strong>FR</strong>-PU07).· Even when motors (other manufacturer's motor, SF-JRC, etc.) other than Mitsubishi standard motor, highefficiency motor (SF-JR SF-HR 3.7kW or more), Mitsubishi constant-torque motor (SF-JRCA four-pole, SF-HRCA3.7kW or more) and vector control dedicated motor (SF-V5RU (1500r/min series)) are used or the wiring length islong, using the offline auto tuning function runs the motor with the optimum operating characteristics.· Tuning is enabled even when a load is connected to the motor. (As the load is lighter, tuning accuracy is higher.Tuning accuracy does not change even if the inertia is large.)· For the offline auto tuning, you can select either the motor non-rotation mode (Pr. 96 = "1") or rotation mode (Pr. 96= "101").· The rotation mode has higher tuning accuracy than the non-rotation mode.· Reading/writing/copy of motor constants tuned by offline auto tuning are enabled.· The offline auto tuning status can be monitored with the PU (<strong>FR</strong>-DU07/<strong>FR</strong>-PU07/<strong>FR</strong>-PU04).· Do not use an inverter with a surge voltage suppression filter (<strong>FR</strong>-ASF-H) connected between the inverter and motor.172

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!