Causes and corrective actionsOperation PanelIndicationE. 1 toE. 3to<strong>FR</strong>-PU04<strong>FR</strong>-PU07Fault 1 to Fault 3NameDescriptionCheck pointCorrective actionOption faultStops the inverter output if a contact faullt, etc. of the connector between the inverter and plug-in optionoccurs or if a communication option is fitted to the connector 1 or 2.Appears when the switch for the manufacturer setting of the plug-in option is changed.1. Check that the plug-in option is plugged into the connector securely.(1 to 3 indicate the option connector numbers.)2. Check for excess electrical noises around the inverter.3. Check that the communication option is not fitted to the connector 1 or 2.1. Connect the plug-in option securely.2. Take measures against noises if there are devices producing excess electrical noises around the inverter.If the problem still persists after taking the above measure, please contact your sales representative ordistributor.3. Fit the communication option to the connector 3.4. Return the switch for the manufacturer setting of the plug-in option to the initial status. (Refer toinstruction manual of each option)Operation PanelIndicationNameDescriptionCheck pointCorrective action<strong>FR</strong>-PU04E.PECorrupt Memry<strong>FR</strong>-PU07Parameter storage device fault (control circuit board)Stops the inverter output if fault occurred in the parameter stored. (EEPROM failure)Check for too many number of parameter write times.Please contact your sales representative.When performing parameter write frequently for communication purposes, set "1" in Pr. 342 to enableRAM write. Note that powering off returns the inverter to the status before RAM write.Operation Panel<strong>FR</strong>-PU04 Fault 14E.PE2Indication<strong>FR</strong>-PU07 PR storage alarmNameParameter storage device fault (main circuit board)Description Stops the inverter output if fault occurred in the parameter stored. (EEPROM failure)Check point ——————Corrective action Please contact your sales representative.Operation PanelIndicationNameDescriptionCheck pointCorrective actionOperation PanelIndicationNameDescriptionCheck pointCorrective action<strong>FR</strong>-PU04E.PUEPU Leave Out<strong>FR</strong>-PU07PU disconnection· This function stops the inverter output if communication between the inverter and PU is suspended,e.g. the operation panel and parameter unit is disconnected, when "2", "3", "16" or "17" was set in Pr.75 Reset selection/disconnected PU detection/PU stop selection.· This function stops the inverter output when communication errors occurred consecutively for morethan permissible number of retries when a value other than "9999" is set in Pr. 121 Number of PUcommunication retries during the RS-485 communication with the PU connector.· This function stops the inverter output if communication is broken within the period of time set in Pr.122 PU communication check time interval during the RS-485 communication with the PU connector.· Check that the <strong>FR</strong>-DU07 or parameter unit (<strong>FR</strong>-PU04/<strong>FR</strong>-PU07) is fitted tightly.· Check the Pr. 75 setting.Fit the <strong>FR</strong>-DU07 or parameter unit (<strong>FR</strong>-PU04/<strong>FR</strong>-PU07) securely.<strong>FR</strong>-PU04E.RETRetry No Over<strong>FR</strong>-PU07Retry count excessIf operation cannot be resumed properly within the number of retries set, this function trips the inverter.Functions only when Pr. 67 Number of retries at fault occurrence is set. When the initial value (Pr. 67 = "0")is set, this protective function does not function.Find the cause of alarm occurrence.Eliminate the cause of the error preceding this error indication.PROTECTIVE FUNCTIONS5383

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!