BENCH MAN’S CON TEST - DRAEGER BG-4Judges’ Working Score cardApparatus Serial # Team No. ________________Test DateBench Per son _____________Visual Inspection Com pany ________________Low Pres sure Alarm(Negative Pressure Warning)In ha la tion ValveEx ha la tion ValveDrain ValvePos i tive Pres sure LeakRe lief ValveCon stant Me ter ing (Dos age)Min i mum ValveBy pass ValveRe sid ual Warn ingBat tery CheckTest OK (ini tials)Replacement PartsReady for UseJudge _________________________Judge _________________________Time to Com plete ProblemMin ______ Sec ______Sum mary of Dis countsWritten test ques tions in cor rect:1 dis count x =Monthly check not per formed:5 dis counts x =Monthly checks out of or der:5 dis counts (to tal)De fi ciency (bug) not found:15 dis counts x = ______De fi ciency (bug) not cor rected:5 dis counts x =Sucking/Blowing Valves:10 dis counts x =Ap pa ra tus not “Ready for Use”:5 dis counts (to tal)Prob lem not com pleted inSpec i fied Time:10 dis counts (to tal) _______To tal Dis countsTime0 Bug _________1st Bug2nd Bug3rd Bug4th Bug5th Bug_____________________________________________53