TESTERSTEP SETTING PROCEDURE HINTS12.By-pass/Con stant Red Dos age Plug re lief valve vent.Dosage Test (0.5 to Press by-pass valve un til2 LPM) nee dle reads 1.7 LPMon out side red scale.Nee dle should set tlebe tween 1.4 <strong>and</strong> 1.7LPM (at sea level).13.Whis tleRe move plug from re liefAc ti va tion valve vent.Close O 2 cyl in der valve.Ob serve chest gauge.Whis tle should sound at20 to 25 per cent of fullcyl in der pres sure.14.Whis tle Du ra tion/ Neg. Pres. Lift pres sure gaugePres sure Gauge Pump ing shut off le ver.Shut offOpen O 2 cyl in der valve.Start stop watch. Whis tleshould sound for 20 to60 sec onds.Chest pres sure gaugeshould read zero.Re turn shut off valve todown po si tion.15.High <strong>and</strong> Me diumPres sure LeakCyl in der valve still open.Check for leaks.Shut off valve af ter test.66