13.07.2015 Views

EMCO WinNC SINUMERIK 810/820 T Software Description ...

EMCO WinNC SINUMERIK 810/820 T Software Description ...

EMCO WinNC SINUMERIK 810/820 T Software Description ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>EMCO</strong> WINNC <strong>SINUMERIK</strong> <strong>810</strong>/<strong>820</strong> TALARMS / MESSAGESH: Alarms and MessagesStartup AlarmsThese alarms can occur only with starting <strong>WinNC</strong> orWinCTS.0001 Error creating the file ...Remedy: Check whether the directories exist, whichare entered in the .INI files.Check whether writing access is possibleto these directories.Check whether the disk is full.0002 Error opening the file ...Remedy: Check whether the directories exist, whichare entered in the .INI files.Check whether reading access is possibleto these directories (number of simultaneousopen files).Copy the correct file in the correspondingdirectory.0003 Error reading the file ...see 0002.0004 Error writing the file ...see 00010005 Too less RAM ...Remedy: Close other WINDOWS applicationsRestart WINDOWS0006 Non compatible software version ...Remedy: <strong>Software</strong> update.0007 Invalid licence version ...Remedy: Contact <strong>EMCO</strong>.0011 Serial interface ... for digitizer is alreadyin useCause:The serial interface no. ... is alreadyoccupied by another device.Remedy: Remove the other device and connect thedigitizer or define another serial interfacefor the digitizer.0012 Serial interface ... for control keyboard isalready in useanalogous to 00110013 Invalid settings for serial interface ...Cause: The actual settings of the serial interfaceare not allowed for <strong>WinNC</strong>.Allowed settings:Baud rate: 110, 300, 600, 1200, 2400,4800, 9600, 19200Number of data bits: 7 or 8Number of stop bits: 1 or 2Parity: none, even or oddRemedy: Change the settings of the serial interfacein the WINDOWS system control (connections).0014 Serial interface ... not presentRemedy: Select an existing serial interface.0015- 0023 (various alarms)Remedy: Restart WINDOWS. If these alarm occurrepeatedly, contact <strong>EMCO</strong>.0024 Invalid entry for control keyboardinterface in the profile ...Cause:The connection of the control keyboard inthe file project.ini is invalid.Remedy: Setting with WinConfig0025 Invalid entry for digitizer interface in theprofile ...analogous to 00240026 Invalid entry for notebook option in theprofile ...Cause:The notebook entry in the file project.ini isinvalid.Remedy: Setting with WinConfig0027 Error creating the start windowRemedy: Restart WINDOWS. If this alarm occursrepeatedly, contact <strong>EMCO</strong>.0028 Invalid entry for window representationin the profile ...Cause:The presentation entry in the file project.iniis invalid.Remedy: Setting with WinConfig0029 Error initializing a timerRemedy: Close all other WINDOWS applications orrestart WINDOWS.0030 Windows 3.1 or higher required<strong>WinNC</strong> requires WINDOWS version 3.1 or higher.0031 - 0036 (various alarms)see 0002H 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!