13.07.2015 Views

EMCO WinNC SINUMERIK 810/820 T Software Description ...

EMCO WinNC SINUMERIK 810/820 T Software Description ...

EMCO WinNC SINUMERIK 810/820 T Software Description ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>EMCO</strong> WINNC <strong>SINUMERIK</strong> <strong>810</strong>/<strong>820</strong> TALARMS / MESSAGES<strong>810</strong>4 Fatal system error ACsee <strong>810</strong>1.<strong>810</strong>5 Fatal init error ACsee <strong>810</strong>1.<strong>810</strong>6 No PC-COM card foundCause: PC-COM board can not be accessed (ev.not mounted).Remedy: Mount board, adjust other address withjumper<strong>810</strong>7 PC-COM card not workingsee <strong>810</strong>6.<strong>810</strong>8 Fatal error on PC-COM cardsee <strong>810</strong>6.<strong>810</strong>9 Fatal error on PC-COM cardsee <strong>810</strong>6.8110 PC-COM init message missingCause: Internal errorRemedy: Restart software or reinstall when necessary,report to <strong>EMCO</strong>, if repeatable.8111 Wrong configuration of PC-COMsee 8110.8113 Invalid data (pccom.hex)see 8110.8114 Programming error on PC-COMsee 8110.8115 PC-COM packet acknowledge missingsee 8110.8116 PC-COM startup errorsee 8110.8117 Fatal init data error (pccom.hex)see 8110.8118 Fatal init error ACsee 8110, ev. insufficient RAM memory8119 PC interrupt no. not validCause: The PC interrupt number can not be used.Remedy: Find out free interrupt number in the Windows95system control (allowed: 5,7,10,11, 12, 3, 4 und 5) and enter this number inWinConfig.8120 PC interrupt no. unmaskablesee 81198121 Invalid command to PC-COMCause: Internal error or defective cableRemedy: Check cables (screw it); Restart softwareor reinstall when necessary, report to<strong>EMCO</strong>, if repeatable.8122 Internal AC mailbox overrunCause: Internal errorRemedy: Restart software or reinstall when necessary,report to <strong>EMCO</strong>, if repeatable.8123 Open error on record fileCause: Internal errorRemedy: Restart software or reinstall when necessary,report to <strong>EMCO</strong>, if repeatable.8124 Write error on record fileCause: Internal errorRemedy: Restart software or reinstall when necessary,report to <strong>EMCO</strong>, if repeatable.8125 Invalid memory for record bufferCause: Insufficient RAM, record time exceeding.Remedy: Restart software, ev. remove drivers etc. togain more RAM, reduce record time.8126 AC Interpolation overrunCause: Ev. insufficient computer performance.Remedy: Set a longer interrupt time in WinConfig.This may result in poorer path accuracy.8127 Insufficient memoryCause: Insufficient RAMRemedy: Close other programs, restart software,ev. remove drivers etc. to gain more RAM.8128 Invalid message to ACCause: Internal errorRemedy: Restart software or reinstall when necessary,report to <strong>EMCO</strong>, if repeatable.8129 Invalid MSD data - axisconfig.see 8128.8130 Internal init error ACsee 8128.8130 Internal init error ACsee 8128.8132 Axis accessed by multiple channelssee 8128.8133 Insufficient NC block memory ACsee 8128.8134 Too much center points programmedsee 8128.8135 No centerpoint programmedsee 8128.8136 Circle radius too smallsee 8128.H 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!