<strong>EMCO</strong> WINNC <strong>SINUMERIK</strong> <strong>810</strong>/<strong>820</strong> TALARMS / MESSAGES2520 ORDxx RS485 device absentCause: With program start not all necessary RS485participant were present or while programrun a participant failed.(AC) Axis controller(SPS) PLC(MT) Control keyboardRemedy: switch on RS485 participant (machine,control keyboard), check cables andconnectors, check terminator plug, reportto <strong>EMCO</strong> if repeatable2521 ORDxx RS485 communication errorRemedy: switch off / on the PC, report to <strong>EMCO</strong> ifrepeatable2522 ORDxx RS485 communication errorCause: internal errorRemedy: switch on/off PC, report to <strong>EMCO</strong> ifrepeatable2523 ORDxx INIT error on RS485 PC-boardsee "Installation of the <strong>Software</strong>, Mistakes with Installationof the <strong>Software</strong>"2524 ORDxx Gen.-Failure RS485 PC-boardRemedy: switch off/on PC, report to <strong>EMCO</strong> ifrepeatable2525 ORDxx Transmit error RS485Remedy: check RS485 cables and connectors, checkterminator plug, check for externalelectromagnetic interferences2526 ORDxx Transmit error RS485see 25252527 ORDxx Internal error ACRemedy: switch off/on machine, report to <strong>EMCO</strong> ifrepeatable2528 ORDxx Operating system error PLCRemedy: switch off/on machine, report to <strong>EMCO</strong> ifrepeatable2529 ORDxx External keyboard errorRemedy: The control keyboard must be switched onafter the PC when it is connected to RS232,switch off/on external keyboard, report to<strong>EMCO</strong> if repeatable2540 ORDxx Error on storing setting-dataCause: hard disk full, wrong path determined, missingwrite accessRemedy: check hard disk, if repeatable reinstallsoftware2545 ORDxx Drive / Device not readyRemedy: insert disk, close drive2546 ORDxx Checksum error machine-dataRemedy: report to <strong>EMCO</strong> if repeatable2550 ORDxx PLC simulation errorRemedy: report to <strong>EMCO</strong> if repeatable2551 ORDxx PLC simulation errorRemedy: report to <strong>EMCO</strong> if repeatable2562 Read error on CNC programCause: error of program file, disk or hard disk errorRemedy: solve problem on DOS level, eventuallyreinstall software2614 Nxxxx Internal error MSDRemedy: report to <strong>EMCO</strong> if repeatable2650 Nxxxx Wrong Cycle-CallCause: invalid cycle call, if cycle will be called withG codeRemedy: report to <strong>EMCO</strong> if repeatable2849 Nxxxx Internal error CRCRemedy: report to <strong>EMCO</strong> if repeatable2904 Nxxxx Helix Z path too largeThe angle between the helix and the tangent to thearc must be less than 45°.Remedy: correct program3000 Nxxxx General Program errorCause: no circle parameter programmed, wrongplane for circle (G17/18/19), chamfer/radius/thread pitch already programmed,thread pitch missing, ...Remedy: correct program3001 Nxxxx More than 5 geomety parameterCause: wrong parameter for contour draftRemedy: correct program3002 Nxxxx Polar/radius errorCause: No centre point specified, centre point inwrong plane (G17/18/19)Remedy: correct program3003 Nxxxx Invalid addressThe entered address is not allowed.Remedy: correct program3004 Nxxxx CL800 ErrorCause: general cycle error with cycle language CL-800, wrong parameter, invalid value,incorrect contour program, M17 in contourprogram missingRemedy: correct program3005 Nxxxx Contour definition errorCause: no valid contour draft with the programmedcoordinates, invalid parameter, invalidvaluesRemedy: correct programH 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!