<strong>SIM300D</strong> <strong>AT</strong> <strong>Comm<strong>and</strong></strong> <strong>Set</strong><br />
Confidential SIMCOM<br />
Reference<br />
Parameter<br />
7.2.7 <strong>AT</strong>+CALARM <strong>Set</strong> alarm<br />
<strong>AT</strong>+CALARM <strong>Set</strong> alarm<br />
Read <strong>Comm<strong>and</strong></strong><br />
<strong>AT</strong>+CALAR<br />
M=?<br />
<strong>Set</strong> <strong>Comm<strong>and</strong></strong><br />
<strong>AT</strong>+CALAR<br />
M=<br />
,,,<br />
currentUart<br />
1 use serial line 1<br />
2 use serial line 2(gprs)<br />
3 use serial line 2<br />
4 last commond use serial line 1<br />
5 last commond use serial line 2<br />
Uart<br />
1 use serial line 1<br />
2 use serial line 2(gprs)<br />
3 use serial line 2<br />
Baud ( If uart is 2 or 3)<br />
9600,19200,28800,38400,57600,115200<br />
Response :<br />
+ CALARM: ,,,<br />
ok<br />
Parameter:<br />
See set comm<strong>and</strong><br />
Response :<br />
ok<br />
Parameter:<br />
< state > an integer parameter which indicates whether enable or disable<br />
alarm.<br />
0 CLEAR ALARM<br />
1 SET ALARM<br />
< time > a string parameter which indicates the time when alarm arrives.<br />
<strong>SIM300D</strong>_<strong>AT</strong>_V1.00 Page 138 of 180<br />
The format is “yy/MM/dd,hh:mm:ss+-zz” where characters<br />
indicate the last two digits of year, month, day, hour, minute,<br />
second <strong>and</strong> time zone. The time zone is expressed in quarters of<br />
an hour between the local time <strong>and</strong> GMT, ranging from -47 to<br />
+48.<br />
< repeat > an integer parameter which indicates the repeat mode<br />
0 None<br />
1 Daily<br />
2 Weekly<br />
3 Monthly<br />
an integer parameter which indicates the method of dealing power