<strong>SIM300D</strong> <strong>AT</strong> <strong>Comm<strong>and</strong></strong> <strong>Set</strong><br />
Confidential SIMCOM<br />
2.2.21 <strong>AT</strong>S6 <strong>Set</strong> pause before blind dialing<br />
<strong>AT</strong>S6 <strong>Set</strong> pause before blind dialing<br />
Read comm<strong>and</strong><br />
<strong>AT</strong>S6?<br />
<strong>Set</strong> comm<strong>and</strong><br />
<strong>AT</strong>S6=[]<br />
Reference<br />
V.25ter<br />
Response<br />
<br />
OK<br />
Response<br />
OK<br />
Parameter<br />
0-2-255 number of seconds to wait before blind dialing<br />
Note<br />
� No effect for GSM<br />
2.2.22 <strong>AT</strong>S7 set number of seconds to wait for connection completion<br />
<strong>AT</strong>S7 <strong>Set</strong> number of seconds to wait for connection completion<br />
Read comm<strong>and</strong><br />
<strong>AT</strong>S7?<br />
<strong>Set</strong> comm<strong>and</strong><br />
<strong>AT</strong>S7=[]<br />
Reference<br />
V.25ter<br />
Response<br />
<br />
OK<br />
Response<br />
This parameter setting determines the amount of time to wait for the<br />
connection completion in case of answering or originating a call.<br />
OK<br />
Parameter<br />
0-60-255 number of seconds to wait for connection completion<br />
Note<br />
� If called party has specified a high value for <strong>AT</strong>S0=, call setup<br />
may fail.<br />
� The correlation between <strong>AT</strong>S7 <strong>and</strong> <strong>AT</strong>S0 is important<br />
Example: Call may fail if <strong>AT</strong>S7=30 <strong>and</strong> <strong>AT</strong>S0=20.<br />
� <strong>AT</strong>S7 is only applicable to data call.<br />
2.2.23 <strong>AT</strong>S8 set number of second to wait for comma dial modifier<br />
<strong>AT</strong>S8 <strong>Set</strong> number of second to wait for comma dial modifier<br />
Read comm<strong>and</strong><br />
<strong>AT</strong>S8?<br />
<strong>Set</strong> comm<strong>and</strong><br />
<strong>AT</strong>S8=[]<br />
Reference<br />
V.25ter<br />
Response<br />
<br />
OK<br />
Response<br />
OK<br />
Parameter<br />
0 no pause when comma encountered in dial string<br />
Note<br />
� No effect for GSM<br />
1-255 number of seconds to wait<br />
<strong>SIM300D</strong>_<strong>AT</strong>_V1.00 Page 22 of 180