<strong>SIM300D</strong> <strong>AT</strong> <strong>Comm<strong>and</strong></strong> <strong>Set</strong><br />

Confidential SIMCOM<br />

529 Incorrect PDU length<br />

530 Invalid MTI<br />

531 Invalid (non-hex) chars in address<br />

532 Invalid address (no digits read)<br />

533 Incorrect PDU length (UDL)<br />

534 Incorrect SCA length<br />

536 Invalid First Octet (should be 2 or 34)<br />

537 Invalid <strong>Comm<strong>and</strong></strong> Type<br />

538 SRR bit not set<br />

539 SRR bit set<br />

540 Invalid User Data Header IE<br />

10<strong>AT</strong> <strong>Comm<strong>and</strong></strong>s Sample<br />

10.1 Profile <strong>Comm<strong>and</strong></strong>s<br />

Demonstration Syntax Expect Result<br />

The <strong>AT</strong> comm<strong>and</strong> interpreter is<br />

actively responding to input.<br />

Display product identification<br />

information: the manufacturer, the<br />

product name <strong>and</strong> the product<br />

revision information.<br />

Display current configuration, a list<br />

of the current active profile<br />

parameters.<br />

Reporting of mobile equipment<br />

errors. The default CME error<br />

reporting setting is disabled.<br />

Switching to verbose mode displays<br />

a string explaining the error in more<br />

details.<br />

Storing the current configuration in<br />

nonvolatile memory. When the<br />

board is reset, configuration changes<br />

from the last session are loaded.<br />

<strong>Set</strong> the ME to minimum<br />

functionality<br />

<strong>SIM300D</strong>_<strong>AT</strong>_V1.00 Page 172 of 180<br />

<strong>AT</strong> OK<br />

<strong>AT</strong>I<br />

SIMCOM_Ltd<br />

SIMCOM_<strong>SIM300D</strong><br />

Revision:<br />

1008B02<strong>SIM300D</strong>_<strong>AT</strong>MEL<br />

<strong>AT</strong>&V [A complete listing of the<br />

<strong>AT</strong>+CMEE=?<br />

<strong>AT</strong>+CMEE?<br />

<strong>AT</strong>+CSCS=?<br />

<strong>AT</strong>+CSCS=”TEST”<br />

<strong>AT</strong>+CMEE=2<br />

<strong>AT</strong>+CSCS=”TEST”<br />

<strong>AT</strong>E0;&W<br />

<strong>AT</strong><br />

[Reset the board]<br />

<strong>AT</strong><br />

<strong>AT</strong>E1;&W<br />

<strong>AT</strong><br />

active profile]<br />

+CMEE:(0,1,2)<br />

+CMEE:0<br />

+CSCS:”GSM”<br />

+CSCS:”UCS2”<br />

ERROR<br />

OK<br />

+CME ERROR: +CSCS<br />

type not found<br />

OK<br />

[No echo]<br />

OK<br />

<strong>AT</strong>+CFUN=0 OK<br />

[No echo]<br />

[Echo on]