SECTION C | CONCRETE<br />

FLAT JACKS - TESTS ON BRICKWORKS<br />

DETERMINATION OF RESISTANCE AND DEFORMATION UNDER LOAD<br />

EVALUATION OF TENSILE STRESS<br />

MEASUREMENT OF ELASTIC MODULUS AND BREAKING LOAD<br />

The complete test is developed in two steps:<br />

DETERMINATION OF STATIC LOAD (TENSILE STATUS)<br />

One flat jack is used.<br />

Two datum points are fixed across a mortar joint and the distance between the points is measured.<br />

Successively a horizontal cut is carried out with the suitable tool (drill, cutting saw) level with the mortar layer, and it is measured the variation<br />

of the two datum points.<br />

The flat jack must be introduced, it is pressurized in different growing phases and the variation between the datum points is measured, by<br />

determining the static load.<br />

DETERMINATION OF DEFORMATION AND RESISTANCE (IN-SITU STRESS)<br />

Two flat jacks are used.<br />

It must be done a second cut, parallel to the first one, level with the mortar layer, having a distance of approximately 50 cm from the first cut.<br />

Another flat jack must be introduced.<br />

Three couples of datum points are placed on the brickwork portion between the two cuts.<br />

Start to pressurize the two flat jacks at growing phases.<br />

The variation of distances of the datum points at different pressure steps allows to delineate a strength-deformation curve, obtaining elastic<br />

modulus, Poisson and breaking point values.<br />

C358-01<br />

RECTANGULAR FLAT JACK high deformability, max. pressure<br />

50 bar, dimensions 400x200x4 mm. Steel sheet 0.8 mm thick<br />

Complete with nuts and groins.<br />

C358-05<br />

STOPCOCK (valve) high pressure complete with fittings, to close the<br />

oil flow in the jack and stop the pressure.<br />

LOAD APPLICATION<br />

C358-01<br />

C358-05<br />

C358-02<br />

C358-11<br />

N° 6 STEEL SHEETS, dimensions 400x200 mm, three pieces 1 mm<br />

thick, three pieces 1.5 mm thick<br />

C358-06 HYDRAULIC HAND PUMP, complete with integral reservoir<br />

with oil, to apply pressure to the jacks.<br />

C358-15 Flexible rubber TUBE, 3 meters length, for the connection<br />

to one jack.<br />

or:<br />

C358-16 Flexible rubber DOUBLE TUBE, 2 and 3 meters length,<br />

for the connection to two jacks.<br />

C358-08 MANOMETER high precision 0 - 60 bar range, with<br />

fast jack, to be fixed on the pump to read the applied<br />

pressure.<br />

C358-08<br />

C358-06<br />

C358-11 C358-12<br />

C358-02<br />

SEMI-OVAL FLAT JACK ad high deformability, max. pressure 50 bar,<br />

dimensions 350x260x4 mm. Steel sheet 0.8 mm thick.<br />

Complete with nuts and groins.<br />

C358-12<br />

N° 6 STEEL SHEETS, dimensions 350x260 mm, three pieces 1 mm<br />

thick, three pieces 1.5 mm thick.<br />

C358-23N<br />

C358-15