SECTION S | SOIL<br />

549<br />

MEASURE OF THE AXIAL STRAIN<br />

Two different equipments are available to measure<br />

the specimen axial displacement:<br />

- Dial gauges (manual readings)<br />

or:<br />

- Displacement transducers<br />

(automatic readings)<br />

S335-15<br />

S336-11<br />

S305-05<br />

DIAL GAUGES (manual readings)<br />

S336-15<br />

S377 Dial gauge, 25x0.01 mm suitable for specimens of max.<br />

dimensions 50x100 mm<br />

S379 Dial gauge, 50x0.01 mm suitable for specimens of max.<br />

dimensions 70x140 mm<br />

S383 Dial gauge, 25.4x0.001 mm with RS 232 port for PC<br />

connection.<br />

Note: For other requirements, dial and digital gauges with different<br />

maximum travel and sensibility are also available:<br />

see technical details at p. 574.<br />

S336-31<br />

Note: The displacement transducers must be connected to the<br />

automatic data acquisition system mod. S334<br />

(see p. 559) or mod. S301-05 (see p. 544).<br />

ACCESSORIES for DISPLACEMENT TRANSDUCERS<br />

S377<br />

S379<br />

S383<br />

S336-30 Extension cable 2 metres long<br />

S336-31 Extension cable 5 metres long<br />

S336-32 Extension cable 10 metres long<br />

Note: It is recommended to use not more than 10 m of extension<br />

cable to avoid noise problems that might occur.<br />

DISPLACEMENT TRANSDUCERS (automatic readings)<br />

Electrical devices for automatic readings. Calibration certificate is<br />

supplied. Cable, connector and signal conditioner are provided.<br />

TYPES OF AVAILABLE TRANSDUCERS:<br />

TYPE “A”: Accurate and versatile linear potentiometric displacement<br />

transducer,.<br />

Indipendent linearity < 0.3% (0.3x10 mm)<br />

Max. displacement speed: up to 10 m/s.<br />

S335-15 Universal coupling pliers to hold the transducer/dial<br />

gauge. It fits all <strong>Matest</strong> displacement transducers and<br />

dial gauges (from Ø 8 mm to 20 mm).<br />

S305-05 Mounting device of the universal coupling pliers mod.<br />

S335-15 to fix the displacement transducer/dial gauge<br />

to the Triaxial Cell mod. S305 or mod. S306<br />

MODELS<br />

S336-11 10 mm travel<br />

S336-12 25 mm travel<br />

S336-14 50 mm travel<br />

S336-13 100 mm travel<br />

TYPE “B”: Linear Strain Gauge Transducer. It guarantees good<br />

repeatability and noise reduction.<br />

Full bridge at 350 Ohm<br />

Indipendent linearity < 0.1%<br />

Standard sensitivity: 2 mV/V<br />

MODELS<br />

S336-18 5 mm travel<br />

S336-15 10 mm travel<br />

S336-16 25 mm travel<br />

S336-17 50 mm travel<br />

S336-41<br />

GAUGE BLOCKS. Grade 1<br />

Used to calibrate the linear displacement transducers.<br />

MODELS<br />

S336-43<br />

S336-45<br />

S336-41 Nominal length 5 mm<br />

S336-43 Nominal length 10 mm<br />

S336-45 Nominal length 25 mm<br />

S336-47 Nominal length 50 mm<br />

S336-47