20.04.2020 Views

VGB POWERTECH 11 (2019)

VGB PowerTech - International Journal for Generation and Storage of Electricity and Heat. Issue 11 (2019). Technical Journal of the VGB PowerTech Association. Energy is us! Power plant operation: legal & technology. Pumped hydro storage. Latent heat storages.

VGB PowerTech - International Journal for Generation and Storage of Electricity and Heat. Issue 11 (2019).
Technical Journal of the VGB PowerTech Association. Energy is us!
Power plant operation: legal & technology. Pumped hydro storage. Latent heat storages.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Digital nuclear security level DCS main and auxiliary data distribution based on NASPIC platform <strong>VGB</strong> PowerTech <strong>11</strong> l <strong>2019</strong><br />

based on NASPIC platform, the other security<br />

level platforms mentioned above do<br />

not have TU transmission stations, which<br />

will reduce the number of cabinets, but<br />

there is a risk that the load of the main processor<br />

is large and the response time is relatively<br />

long.<br />

Conclusions<br />

Through the in-depth analysis and research<br />

of the security level DCS architecture,<br />

the data transmission mode of the<br />

main and auxiliary data shunting is proposed,<br />

which gives priority to ensuring the<br />

safe and reliable processing and transmission<br />

of the main data directly related to the<br />

security function. The distribution of auxiliary<br />

function data in TU station effectively<br />

reduces the load of main function data<br />

transmission channels, improves the realtime<br />

and reliability of the system, and ensures<br />

the safe and reliable operation of nuclear<br />

power plant. The distribution technology<br />

of main and auxiliary data has been<br />

successfully applied to many projects, and<br />

has achieved good engineering application<br />

results.<br />

References<br />

[1] Zhang Rui, Peng Huaqing. Digital reactor<br />

control system research [J]. Nuclear Power<br />

Engineering, 2002 (5): 86-88.<br />

[2] Liu Yue, Ding Changfu. Analysis and research<br />

of DCS security level instrumentation platform<br />

[J]. Automation Expo, 2012 (1): 48-<br />

52. l<br />

<strong>VGB</strong>-Standard<br />

Structural Design of Cooling Towers<br />

<strong>VGB</strong> Standard on the Structural Design, Calculation, Engineering<br />

and Construction of Cooling Towers<br />

Edition <strong>2019</strong> – <strong>VGB</strong>-S-610-00-<strong>2019</strong>-10-EN (English edition)<br />

<strong>VGB</strong>-S-610-00-<strong>2019</strong>-10-DE (German edition)<br />

eBook (PDF)/print DIN A4, 86 pa ges,<br />

ISBN: 978-3-96284-145-4 (print), ISBN: 978-3-96284-146-1 (eBook)<br />

Pri ce for <strong>VGB</strong> mem bers € 180.–,<br />

for non mem bers € 270.–, + VAT, ship ping and hand ling.<br />

eBook (PDF)/Druckfassung DIN A4, 86 Seiten,<br />

ISBN: 978-3-96284-143-0 (print), ISBN: 978-3-96284-144-7 (eBook)<br />

Preis für <strong>VGB</strong>-Mit glie der € 180,–,<br />

für Nicht mit glie der € 270,–, + Ver sand kos ten und MwSt.<br />

<strong>VGB</strong>-Standard<br />

Structural Design of<br />

Cooling Towers<br />

<strong>VGB</strong>-Standard on the Structural Design,<br />

Calculation, Engineering and Construction<br />

of Cooling Towers<br />

(formerly <strong>VGB</strong>-R 610e)<br />

<strong>VGB</strong>-S-610-00-<strong>2019</strong>-10-DE<br />

Summary<br />

This <strong>VGB</strong> Standard <strong>VGB</strong>-S-610, “Structural Design of Cooling Towers” constitutes the joint basis – together with <strong>VGB</strong>-R 135e,<br />

“Planning of Cooling Towers”, and <strong>VGB</strong>-R 612e, “Protection Measures on Reinforced Concrete Cooling Towers and Chimneys<br />

against Operational and Environmental Impacts” – for the civil engineering-related planning including design, construction and<br />

approval as well as for the construction of cooling tower facilities built from reinforced concrete. It is based on more than 50 years<br />

of experience in the construction of cooling towers gained by plant and structural design engineers, by construction companies,<br />

accredited review engineers and owners. In addition, Guideline <strong>VGB</strong>-R 613e, “Code of Practice for Life Cycle Management of<br />

Reinforced Concrete Cooling Towers at Power Plants”, presents notes on in-process inspection and maintenance.<br />

The <strong>VGB</strong> Standard was thoroughly revised and restructured compared with the last edition, <strong>VGB</strong>-R 610e of 2010, chiefly in order<br />

to increase its application and ac-ceptance by potential users outside Germany. To this end its structure was modified to make it<br />

similar to the European standards by dividing into a generally valid and internationally oriented base part and a specific national,<br />

i.e., German part. Different from the European standards, however, no national annex was created. Instead, for improved readability<br />

a unified document was produced comprising the generally applicable base part and the location-specific part (on a grey<br />

background) with German rules. For application outside Germany it is necessary to use the respective national rules and specifications<br />

instead of the German rules.<br />

New findings from continued engineering studies and feedback from practice have also necessitated modifications. In particular,<br />

hybrid cooling towers and multi-cell cooling towers as now common cooling tower design variants have been included, in addition<br />

to natural draught cooling towers.<br />

This <strong>VGB</strong> Standard does not cover contractual arrangements with responsibilities for organisational workflows. These are to be defined<br />

separately by the contracting par-ties. Users are requested to inform the <strong>VGB</strong> Office of their experience with the appli-cation<br />

of this <strong>VGB</strong> Standard and any sources of possible misinterpretation or short-falls in presentation, and to make suggestions for improvements.<br />

These may be tak-en as a basis for future additions or amendments.<br />

This <strong>VGB</strong> Standard <strong>VGB</strong>-S-610e, “Structural Design of Cooling Towers”, supersedes <strong>VGB</strong> Guideline <strong>VGB</strong>-R 610e of 2010 with the<br />

same name.<br />

<strong>VGB</strong> PowerTech Service GmbH Deilbachtal 173 | 45257 Essen | P.O. Box 10 39 32 | Germany<br />

T: +49 201 8128-200 | F: +49 201 8128-302 | E: mark@vgb.org | www.vgb.org/shop<br />

62

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!