For intermediate-length columns with effective-slenderness ratios between 9.5 and 66,

σ allow = [20.2 − 0.125( KL/ r)] ksi

KL

(16.27)

= [139 − 0.868( KL/ r)] MPa where 9.5 < ≤ 66

r

699

EMPIRICAL COLuMN

FORMuLAS—

CENTRIC LOAdINg

For long columns with effective-slenderness ratios greater than 66,

51,000

σ allow = ksi

2

( KL/ r)

351,000

KL

= MPa where > 66

2

( KL/ r)

r

(16.28)

Wood columns

The design of wood structural members is governed by the document National Design Specification

for Wood Construction with Supplement, published by the American Wood Council

(AWC). 3 The National Design Publication Specification (NDS) provides a single formula for

the design of rectangular wood columns. The format of this formula differs somewhat from

that of the formulas for steel and aluminum in that the effective-slenderness ratio is expressed

as KL/d, where d is the finished dimension of the rectangular cross section. The effectiveslenderness

ratio for wood columns must satisfy KL/d ≤ 50. The NDS formula is

σ =

allow

⎧⎪

1 + ( F / F )

Fc

2c

⎩⎪

⎡1 + ( F / F ) ⎤

⎣⎢ 2c

⎦⎥

− F / F ⎫⎪

c

⎭⎪

2

cE c cE c cE c

(16.29)

where

F c = allowable stress for compression parallel to grain,

0.822Emin

FcE

=

= reduced Euler buckling stress,

2

( KL/ d)

E′ min = adjusted modulus of elasticity for stability calculations, and

c = 0.8 for sawn lumber.

The effective-slenderness ratio KL/d is taken as the larger of KL/d 1 or KL/d 2 , where d 1 and

d 2 are the two finished dimensions of the rectangular cross section.

Local Instability

All of the discussion so far has been concerned with the overall stability of the column, in

which the entire column length deflects as a whole into a smooth curve. However, no discussion

of compression loading is complete without mentioning local instability. Local instability

occurs when elements of the cross section, such as a flange or a web, buckle because of the

compressive load acting on them. Open sections such as angles, channels, and W sections are

particularly sensitive to local instability, although it can be a concern with any thin plate or

shell element. To address local instability, design specifications typically define limits on the

acceptable width-to-thickness ratios for various types of cross-sectional elements.

3

National Design Specification for Wood Construction, American Wood Council, Leesburg, VA, 2015.

Hooray! Your file is uploaded and ready to be published.