The reduced Euler buckling stress term used in the AWC NDS formula has the value

F

cE

=

0.822E′

( KL/ d)

0.822(400,000 psi)

= = 468.92 psi

(26.48)

min

2 2

Also,

F

F

cE

c

468.92 psi

= = 0.4809

975 psi

This ratio, along with the values F c = 975 psi and c = 0.8 (for sawn lumber), are used in

the AWC NDS formula to calculate the allowable compression stress for the timber

column:

σ

allow

⎧⎪

1 + ( F / F )

= Fc

⎩⎪ 2c

= (975 psi) 1 +

(0.4809) −

2(0.8)

2

⎡1 + ( F / F ) ⎤

F / F

⎣⎢

2c

⎦⎥ − ⎪

c

⎭⎪

⎡1 + (0.4809) ⎤

⎢ ⎥ −

⎣ 2( 0.8)

2

= (975 psi) 0.9256 − 0.9256 − 0.6011

= 409.5 psi

cE c cE c cE c

{ }

2

0.4809

0.8

The allowable axial load that may be supported by the column is therefore

P = σ A = (409.5 psi)(7.25 in.)(9.25 in.) = 27,462 lb = 27,500 lb Ans.

allow

allow

pRoBLEmS

p16.27 Use the AISC equations to determine the allowable

axial load P allow that may be supported by a W8 × 48 wide-flange

column for the following effective lengths: (a) KL = 13 ft and

(b) KL = 26 ft. Assume that E = 29,000 ksi and σ Y = 50 ksi.

z

x

P

y

p16.28 Use the AISC equations to determine the allowable

axial load P allow that may be supported by an HSS152.4 × 101.6 × 6.4

column for the following effective lengths: (a) KL = 3.75 m and

(b) KL = 7.5 m. Assume that E = 200 GPa and σ Y = 320 MPa.

p16.29 The 10 m long HSS304.8 × 203.2 × 9.5 (see Appendix B

for cross-sectional properties) column shown in Figure P16.29/30

is fixed at base A with respect to bending about both the strong and

weak axes of the HSS cross section. At upper end B, the column is

restrained against rotation and translation in the x–z plane (i.e.,

bending about the weak axis) and against translation in the x–y

plane (i.e., the column is free to rotate about the strong axis). Use

the AISC equations to determine the allowable axial load P allow that

may be supported by the column, on the basis of (a) buckling in

the x–y plane and (b) buckling in the x–z plane. Assume that

E = 200 GPa and σ Y = 320 MPa.

B

A

FIGURE p16.29/30

p16.30 The 25 ft long HSS6 × 4 × 1/8 (see Appendix B for

cross-sectional properties) column shown in Figure P16.29/30 is

L

z

Strong

axis

Weak

axis

y

704