From this allowable stress, the allowable axial load can be computed as

2 2

P = σ A = (91.43 N/mm )(804 mm ) = 73,510 N = 73.5 kN Ans.

allow

allow

(b) Allowable axial load P allow for KL = 2,750 mm: For an effective length KL = 2,750 mm,

the effective-slenderness ratio is

KL

r

= 2,750 mm

27.38 mm = 100.4

Since this slenderness ratio is greater than 66, the allowable compression stress is determined

from Equation (16.28):

351,000 351,000

σ allow = MPa = = 34.82 MPa

2 2

( KL/ r)

(100.4)

The allowable axial load is therefore

2 2

P = σ A = (34.82 N/mm )(804 mm ) = 27,995 N = 28.0 kN Ans.

allow

allow

ExAmpLE 16.7

A sawn rectangular timber of visually graded No. 2 Spruce–Pine–Fir (SPF) wood has

finished dimensions of 7.25 in. by 9.25 in. For this wood species and grade, the allowable

compression stress parallel to the wood grain is F c = 975 psi and the modulus of elasticity

is E′ min = 400,000 psi. The timber column has a length L = 16 ft, and pinned connections

are used at each end of the column. Use the AWC National Design Specification for Wood

Construction (NDS) column design formula to determine the allowable axial load P allow

that may be supported by the column.

Plan the Solution

The AWC NDS column design formula given in Equation (16.29) will be used to compute

the allowable axial load.

z

y

7.25 in.

9.25 in.

SolutioN

The AWC NDS column design formula is

where

⎧⎪

1 + ( F / F )

σ allow = Fc

⎩⎪ 2c

2

⎡1 + ( F / F ) ⎤

( F / F )

⎣⎢

2c

⎦⎥ − ⎪

c

⎭⎪

cE c cE c cE c

F c = allowable stress for compression parallel to grain,

0.822Emin

FcE

= = reduced Euler buckling stress,

2

( KL/ d)

E′ min = adjusted modulus of elasticity for stability calculations, and

c = 0.8 for sawn lumber.

The finished dimensions of the timber column are 7.25 in. by 9.25 in. The smaller of

these two dimensions is taken as d in the term KL/d. Since the column has pinned ends,

the effective-length factor is K = 1.0; therefore,

KL

d

(1.0)(16 ft)(12 in./ft)

= = 26.48

7.25 in.

703