MODEL<br />

ice flag (0)<br />

&fdda<br />

(for grid nudging)<br />

for grid, obs and spectral nudging<br />

grid_fdda (max_dom) 1 grid analysis nudging on (=0 off)<br />

2 spectral analysis nudging option<br />

gfdda_inname “wrffdda_d” defined name in real<br />

gfdda_interval<br />

(max_dom)<br />

360 Time interval (min) between analysis<br />

times<br />

gfdda_end_h (max_dom) 6 Time (h) to stop nudging after start of<br />

forecast<br />

io_form_gfdda 2 analysis format (2 = netcdf)<br />

fgdt (max_dom) 0 calculation frequency (in minutes) for<br />

analysis nudging. 0 = every time step, and<br />

this is recommended<br />

fgdtzero 0 not active<br />

1 nudging tendencies are set to zero in<br />

between fdda calls<br />

if_no_pbl_nudging_uv<br />

(max_dom)<br />

if_no_pbl_nudging_t<br />

(max_dom)<br />

if_no_pbl_nudging_q<br />

(max_dom)<br />

if_no_pbl_nudging_ph<br />

(max_dom)<br />

0 1= no nudging of u and v in the pbl; 0=<br />

nudging in the pbl<br />

0 1= no nudging of temp in the pbl; 0=<br />

nudging in the pbl<br />

0 1= no nudging of qvapor in the pbl; 0=<br />

nudging in the pbl<br />

0 1= no nudging of ph in the pbl; 0=<br />

nudging in the pbl; only for spectral<br />

nudging<br />

if_zfac_uv (max_dom) 0 0= nudge u and v in all layers, 1= limit<br />

nudging to levels above k_zfac_uv<br />

k_zfac_uv 10 10=model level below which nudging is<br />

switched off for u and v<br />

if_zfac_t (max_dom) 0 0= nudge temp in all layers, 1= limit<br />

nudging to levels above k_zfac_t<br />

k_zfac_t 10 10=model level below which nudging is<br />

switched off for temp<br />

if_zfac_q (max_dom) 0 0= nudge qvapor in all layers, 1= limit<br />

nudging to levels above k_zfac_q<br />

k_zfac_q 10 10=model level below which nudging is<br />

switched off for water qvapor<br />

<strong>WRF</strong>-<strong>ARW</strong> V3: User’s <strong>Guide</strong> 5-44