&grib2<br />

MODEL<br />

background_proc_id 255 Background generating process identifier,<br />

typically defined by the originating center<br />

to identify the background data that was<br />

used in creating the data. This is octet 13<br />

of Section 4 in the grib2 message<br />

forecast_proc_id 255 Analysis or generating forecast process<br />

identifier, typically defined by the<br />

originating center to identify the forecast<br />

process that was used to generate the data.<br />

This is octet 14 of Section 4 in the grib2<br />

message<br />

production_status 255 Production status of processed data in the<br />

grib2 message. See Code Table 1.3 of the<br />

grib2 manual. This is octet 20 of Section 1<br />

in the grib2 record<br />

compression 40 The compression method to encode the<br />

output grib2 message. Only 40 for<br />

jpeg2000 or 41 for PNG are supported<br />

&dfi_control digital filter option control (does not yet support nesting)<br />

dfi_opt 3 which DFI option to use<br />

0: no digital filter initialization<br />

1: digital filter launch (DFL)<br />

2: diabatic DFI (DDFI)<br />

3: twice DFI (TDFI) (recommended)<br />

dfi_nfilter 7 digital filter type: 0 – uniform; 1- Lanczos;<br />

2 – Hamming; 3 – Blackman; 4 – Kaiser; 5<br />

– Potter; 6 – Dolph window; 7 – Dolph<br />

(recommended); 8 – recursive high-order<br />

dfi_write_filtered_<br />

input<br />

.true. whether to write wrfinput file with filtered<br />

model state before beginning forecast<br />

dfi_write_dfi_history .false. whether to write wrfout files during<br />

filtering integration<br />

dfi_cutoff_seconds 3600 cutoff period, in seconds, for the filter.<br />

Should not be longer than the filter<br />

window<br />

dfi_time_dim 1000 maximum number of time steps for<br />

filtering period, this value can be larger<br />

than necessary<br />

dfi_bckstop_year 2001 four-digit year of stop time for backward<br />

DFI integration. For a model that starts<br />

<strong>WRF</strong>-<strong>ARW</strong> V3: User’s <strong>Guide</strong> 5-51